Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to determine the difference between hand and electronic timing of 40-yd dashes in college football players. National Collegiate Athletic Association Division II players (n = 59) were measured during a 40-yd sprint by electronic timing and simultaneously by 7 experienced hand timers using digital stopwatches. Electronic times were initiated by lifting the hand from a switch mat and stopped by the torso passing through an infrared beam. Hand timers initiated timing on first movement of the player from a 3-point stance. To establish performance and timing reliabilities, 32 players completed a second trial. Interrater reliability for hand timing was intraclass correlation coefficient (ICC) = 0.987 (p < 0.001). Five of the 7 timers did not differ significantly (p > 0.05) in their timing. The maximum difference among the hand timers on any given trial was 0.19 +/- 0.14 seconds, with a 95% confidence interval (CI) of -0.08 to 0.41 seconds. Hand timing (4.85 +/- 0.28 seconds) was significantly faster (p < 0.001) than electronic timing (5.16 +/- 0.28 seconds), producing an average difference of 0.31 +/- 0.07 seconds (6.0 +/- 1.3%) and a 95% CI on the average difference of -0.44 to -0.18 seconds. The correlation between electronic timing and hand timing was ICC = 0.985 (p < 0.001). Practically speaking, electronic timing produces the best measurement of 40-yd dash speed, and using the hand timing produces consistently but significantly faster times.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1519/JSC.0b013e3181c08860 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!