High flow rate microfluidic device for blood plasma separation using a range of temperatures.

Lab Chip

Department of electronics, Physics Faculty, University of Barcelona, C/Martí I Franquès 1, 08028 Barcelona, Spain.

Published: January 2010

A hybrid microfluidic device that uses hydrodynamic forces to separate human plasma from blood cells has been designed and fabricated and the advantageous effects of temperature and flow rates are investigated in this paper. The blood separating device includes an inlet which is reduced by approximately 20 times to a small constrictor channel, which then opens out to a larger output channel with a small lateral channel for the collection of plasma. When tested the device separated plasma from whole blood using a wide range of flow rates, between 50 microl min(-1) and 200 microl min(-1), at the higher flow rates injected by hand and at temperatures ranging from 23 degrees C to 50 degrees C, the latter resulting in an increase in the cell-free layer of up to 250%. It was also tested continuously using between 5% and 40% erythrocytes in plasma and whole blood without blocking the channels or hemolysis of the cells. The mean percentage of plasma collected after separation was 3.47% from a sample of 1 ml. The percentage of cells removed from the plasma varied depending on the flow rate used, but at 37 degrees C ranged between 95.4 +/- 1% and 97.05 +/- 05% at 100 microl min(-1) and 200 microl min(-1), respectively. The change in temperature also had an effect on the number of cells removed from the plasma which was between 93.5 +/- 0.65% and 97.01 +/- 0.3% at 26.9 degrees C and 37 degrees C, respectively, using a flow rate of 100 microl min(-1). Due to its ability to operate in a wide range of conditions, it is envisaged that this device can be used in in vitro 'lab on a chip' applications, as well as a hand-held point of care (POC) device.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b904531gDOI Listing

Publication Analysis

Top Keywords

microl min-1
20
flow rate
12
plasma blood
12
flow rates
12
microfluidic device
8
plasma
8
wide range
8
min-1 200
8
200 microl
8
degrees degrees
8

Similar Publications

The content of benzyl isothiocyanate (BITC) which as the enzymatic hydrolysis product of benzyl glucosinolate through thioglucosidase was determined by HPLC. The content of benzyl isothiocyanate (BITC) which as the enzymatic hydrolysis product of benzyl glucosinolate through thioglucosidase was determined by HPLC. The chromatography condition was as follows: Kaseisorb LC ODS 2000 (4.

View Article and Find Full Text PDF

To study the variation of six ester-type alkaloids and characteristic fingerprints in the process from Radix Aconite Lateralis to Heishunpian and lay a foundation for the study of the processing principle of Heishunpian, HPLC. analysis was performed on a Phenomenex Gemini C18 (4.6 mm x 250 mm, 5 microm) with acetonitrile and 40 mmol x L(-1) ammonium acetate (adjusted to pH 10 with concentrated ammonia water) as mobile phase.

View Article and Find Full Text PDF

In order to establish an UPLC-MS method for determination of twelve active compounds in Qili Qiangxin capsules including astragaloside, calycosin-7-0-glucoside, ginsenoside Rb1, ginsenoside Re, ginsenoside Rd, ginsenoside Rg1, ginsenoside Rf, periplocin, periplocoside H1, hesperidin, narirutin, isoquercitrin, the chromatographic separations were performedon a Phenomenex UPLC Kinetex C18 column (2.1 mm x 100 mm, 2.6 microm) with gradient elution of acetonitrile and 0.

View Article and Find Full Text PDF

This study aims to establish a new method for quality evaluation of Gentianae Macrophyllae Radix by simultaneous determination of five iridoids (loganic acid, 6'-O-beta-D-glucopyranosylgentiopicroside, swertiamarin, gentiopicroside, sweroside), and to detect five iridoids in the root of eight species (Gentiana macrophylla, G. straminea, G. crassicaulis, G.

View Article and Find Full Text PDF
Article Synopsis
  • A quick method was developed to extract and analyze five key compounds (ferulic acid, senkyunolide I, H, A, and ligustilide) from Ligusticum chuanxiong using 40% ethanol and HPLC.
  • The chromatographic separation used an Agilent 1100 series system with a specific gradient elution and monitored at two different wavelengths for optimal detection.
  • The study also assessed the content of these compounds at ten different harvest stages, finding the best collection time between April 15th and May 30th to enhance the quality of L. chuanxiong.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!