Background: Access flow (QA) surveillance is the best method recommended for early stenosis detection, but in native arteriovenous fistula (AVF), the literature is conflicting about the real need for monthly monitoring of QA, as suggested by the K-DOQI Guidelines.

Methods: From 1 January 2006 to 31 October 2007 (mean 18.0 +/- 4.9 months), we prospectively followed up 224 patients with monthly AVF monitoring by means of clinical examination and QB stress test (QBST). Suspected malfunctioning AVFs were referred to ultrasound dilution technique (UDT) and imaging techniques (Doppler ultrasonography, angiography), with eventually further percutaneous angioplasty (PTA) or surgical revision.

Results: We observed a good correlation between QBST and QA measurement obtained by the UDT. Patients with positive QBST had a lower QA than negative QBST subjects (433 +/- 203 vs 1168 +/- 681 ml/min, P < 0.0001). Fifty-four out of 224 (24%) patients were selected for possibly malfunctioning AVF. We found no stenosis in 13 out of 54 (24%) patients, inflow stenosis in 29 out of 54 (54%) patients and outflow stenosis in 12 out of 54 (22%) patients. The QBST positive predictive value for inflow stenosis was 76.3%. The interventional radiologist performed 38 PTA procedures in 33 patients (11 PTA per 100 patient-years) and we surgically created 13 new AVF (3.7 per 100 patient-years). Only five thrombosis episodes occurred in five patients during the follow-up (1.5 thromboses per 100 patient-years).

Conclusions: QBST is a simple, low-cost, not time-consuming test, able to select, together with clinical evaluation, malfunctioning AVF with stenosis located specifically in the inflow tract. Our follow-up data demonstrated that it is possible to achieve a low AVF thrombosis rate by adding QBST in an AVF monitoring program, thus reducing the surveillance burden.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ndt/gfp725DOI Listing

Publication Analysis

Top Keywords

stress test
8
detection native
8
native arteriovenous
8
arteriovenous fistula
8
patients
8
avf monitoring
8
24% patients
8
malfunctioning avf
8
avf stenosis
8
inflow stenosis
8

Similar Publications

Background And Aims: Body composition parameters associated with aerobic fitness, mirrored by maximal oxygen consumption (V̇Omax), have recently gained interest as indicators of physical efficiency in facioscapulohumeral dystrophy (FSHD). Bioimpedance analysis (BIA) allows a noninvasive and repeatable estimate of body composition but is based on the use of predictive equations which, if used in cohorts with different characteristics from those for which the equation was originally formulated, could give biased results. Instead, the phase angle (PhA), a BIA raw bioelectrical parameter reflecting body fluids distribution, could provide reliable data for such analysis.

View Article and Find Full Text PDF

Background: Recently it has been suggested that coronary microvascular dysfunction (CMD) may explain the high false-positive rate of exercise electrocardiographic stress testing (EST). However, patients with angina but non-obstructive coronary artery disease (ANOCA) present with a broader spectrum of coronary vasomotor dysfunction (CVDys), namely coronary artery spasm (CAS), CMD or a combination of both. We aim to investigate the diagnostic value of EST for the entire CVDys spectrum.

View Article and Find Full Text PDF

Examining Changes in Pain Sensitivity Following 8 Minutes of Cycling at Varying Exercise Intensities.

Int J Exerc Sci

December 2024

Rehabilitation and Modulation of Pain (RAMP) Lab, Institute of Exercise Physiology and Rehabilitation Science, University of Central Florida, Orlando, FL, USA.

This study assessed the effect of an eight-minute cycling intervention using varying intensities on exercise-induced hypoalgesia (EIH). The main objective of this study was to examine the effect of varying intensities on pressure pain threshold (PPT) and heat pain threshold (HPT) at the thigh and forearm, tested pre- and post-cycling intervention. Healthy male participants ( = 16) performed a graded exercise test on a cycle ergometer to establish their peak power output (PPO).

View Article and Find Full Text PDF

The high prevalence of obesity and physical inactivity in the U.S. is a public health crisis.

View Article and Find Full Text PDF

Objective: In the course of the EU funded Pandemic Preparedness and Response (PANDEM-2) project, a functional exercise (FX) was conducted to train the coordinated response to a large-scale pandemic event in Europe by using new IT solutions developed by the project. This report provides an overview of the steps involved in planning, conducting, and evaluating the FX.

Methods: The FX design was based on the European Centre for Disease Prevention and Control (ECDC) simulation exercise cycle for public health settings and was carried out over 2 days in the German and Dutch national public health institutes (PHI), with support from other consortium PHIs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!