A solution delivery platform comprised of a suspended microcapillary connected to a microwell enables picogram solute deposition on suspended structures. Precision material placement in the capillary from a 100 pl drop inkjetted into the well is achieved without the destruction of the microstructure and adjacent submicron electrostatic gaps. This method scales to smaller structures without the need for drop miniaturization. The theory behind the solute transfer in the system is developed. Three regions in the drying process are observed and match with the model. The "accumulation" region builds solute concentration in the capillary. The "solidification" region initiates the solidification of solute starting at the free end of the capillary. The "termination" region is characterized by a rapid increase in the solidification due to an increase in the well concentration near the end of the drop lifetime. The accumulation time and solidification rate dependence on concentration compare well with the model.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801575PMC
http://dx.doi.org/10.1063/1.3248305DOI Listing

Publication Analysis

Top Keywords

picogram material
4
material dosing
4
dosing microstructures
4
microstructures solution
4
solution delivery
4
delivery platform
4
platform comprised
4
comprised suspended
4
suspended microcapillary
4
microcapillary connected
4

Similar Publications

Precise and rapid disease detection is critical for controlling infectious diseases like COVID-19. Current technologies struggle to simultaneously identify viral RNAs and host immune antibodies due to limited integration of sample preparation and detection. Here, we present acoustofluidic integrated molecular diagnostics (AIMDx) on a chip, a platform enabling high-speed, sensitive detection of viral immunoglobulins [immunoglobulin A (IgA), IgG, and IgM] and nucleic acids.

View Article and Find Full Text PDF

Antibody-modified 2D MXene nanosheet probes for selective, picolevel detection of cancer biomarkers.

Biosens Bioelectron

March 2025

Centre for Nano and Material Sciences, Jain global Campus, Jain (Deemed-to-be-University), Jakkasandra Post Ramanagaram Dist, 562112, India. Electronic address:

Cancer biomarkers are crucial indicators found in clinical samples, playing a key role in early detection, diagnosis, and treatment of cancer. Detecting these biomarkers with high sensitivity is essential for early diagnosis, especially in aggressive cancers like lung cancer, which is the leading cause of cancer-related deaths. Carcinoembryonic antigen (CEA) is a critical biomarker for lung cancer, and its detection aids in identifying the disease at an early stage.

View Article and Find Full Text PDF

Background: The evaluation of genetic markers in the gingival crevicular fluid (GCF) and their connection to tooth movement can be helpful.

Aim: The objective of this research is to assess the relationship involving leptin levels and orthodontic tooth movement (OTM).

Study Setting And Design: Thirty individuals reporting to the Department of Orthodontics participated in an observational prospective study.

View Article and Find Full Text PDF

Thermal desorption (TD) of wipe-based samples was coupled with an in-line dielectric barrier discharge ionization (DBDI) source and rugged compact time-of-flight mass spectrometer (MS) for the detection of explosives, propellants, and postblast debris. The chromatography-free TD-DBDI-MS platform enabled rapid and sensitive detection of organic nitramine, nitrate ester, and nitroaromatic explosives as well as black powder and black powder substitute propellants. Parametric investigations characterized the response to TD temperature and optimized DBDI voltage, aerodynamically assisted entrainment, and fragmentation through in-source collision induced dissociation (isCID).

View Article and Find Full Text PDF

Mapping elemental solutes at sub-picogram levels during aqueous corrosion of Al alloys using diffusive gradients in thin films (DGT) with LA-ICP-MS.

Anal Bioanal Chem

June 2024

Department of General, Analytical and Physical Chemistry, Chair of General and Analytical Chemistry, Montanuniversität Leoben, Franz-Josef-Strasse 18, 8700, Leoben, Austria.

A novel approach using diffusive gradients in thin films (DGT) with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for two-dimensional mapping of elemental solute release at sub-picogram levels during aqueous corrosion of Al alloys is presented. Evaluation of different DGT gels with mixed micro-sized binding phases (polyacrylamide-Chelex-Metsorb, polyurethane (PU)-Chelex-Metsorb, PU-Chelex-Zr(OH)) demonstrated the superior performance of PU gels due to their tear-proof handling, low shrinkage, and compliance with green chemistry. DGT devices containing PU-Chelex-Zr(OH) gels, which have not been characterized for Al sampling before, showed quantitative uptake of Al, Zn, and Cu solutes over time (t = 4-48 h) with higher Al capacity (Γ = 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!