A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High hip center technique using a biconical threaded Zweymüller cup in osteoarthritis secondary to congenital hip disease. | LitMetric

Background: The high hip center technique used for a deficient acetabulum is reconstruction of the hip at a high center of rotation. In the literature, there is no consensus regarding the value of this technique.

Questions/purposes: We investigated whether the new-generation biconical threaded Zweymüller cup fixed in a high nonanatomic position in patients with arthritis secondary to congenital hip disease experienced different rates of polyethylene wear and long-term survivorship when compared with anatomically positioned cups.

Patients And Methods: We studied the polyethylene wear rate and Kaplan-Meier survivorship of 104 titanium threaded Zweymüller cups in 88 patients (81 females), placed in 70 hips at near-normal hip center and in 34 hips at a high hip center position at a distance of 31.1 to 60 mm (mean, 39.7 mm) from the interteardrop line. Minimum followup was 2 years (mean +/- SD, 8.6 +/- 3.5 years; range, 2-15 years).

Results: The mean linear polyethylene wear rates in the near-normal and high hip center groups were not different (0.110 +/- 0.050 mm and 0.113 +/- 0.057 mm, respectively). The Kaplan-Meier 15-year cup survivorship rates with revision for any reason as an event of interest in the near-normal and high hip center groups also were not different (97.2% [95% confidence interval, 88.5%-99.3%] and 97.1% [95% confidence interval, 73.8%-99.3%], respectively).

Conclusions: The high hip center technique using a biconical threaded Zweymüller cup in patients with arthritis secondary to congenital hip disease results in a polyethylene wear rate and long-term cup survivorship comparable to those observed in anatomically positioned cups.

Level Of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of level of evidence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2882016PMC
http://dx.doi.org/10.1007/s11999-009-1203-1DOI Listing

Publication Analysis

Top Keywords

hip center
28
high hip
24
threaded zweymüller
16
polyethylene wear
16
center technique
12
biconical threaded
12
zweymüller cup
12
secondary congenital
12
congenital hip
12
hip disease
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!