Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The high hip center technique used for a deficient acetabulum is reconstruction of the hip at a high center of rotation. In the literature, there is no consensus regarding the value of this technique.
Questions/purposes: We investigated whether the new-generation biconical threaded Zweymüller cup fixed in a high nonanatomic position in patients with arthritis secondary to congenital hip disease experienced different rates of polyethylene wear and long-term survivorship when compared with anatomically positioned cups.
Patients And Methods: We studied the polyethylene wear rate and Kaplan-Meier survivorship of 104 titanium threaded Zweymüller cups in 88 patients (81 females), placed in 70 hips at near-normal hip center and in 34 hips at a high hip center position at a distance of 31.1 to 60 mm (mean, 39.7 mm) from the interteardrop line. Minimum followup was 2 years (mean +/- SD, 8.6 +/- 3.5 years; range, 2-15 years).
Results: The mean linear polyethylene wear rates in the near-normal and high hip center groups were not different (0.110 +/- 0.050 mm and 0.113 +/- 0.057 mm, respectively). The Kaplan-Meier 15-year cup survivorship rates with revision for any reason as an event of interest in the near-normal and high hip center groups also were not different (97.2% [95% confidence interval, 88.5%-99.3%] and 97.1% [95% confidence interval, 73.8%-99.3%], respectively).
Conclusions: The high hip center technique using a biconical threaded Zweymüller cup in patients with arthritis secondary to congenital hip disease results in a polyethylene wear rate and long-term cup survivorship comparable to those observed in anatomically positioned cups.
Level Of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of level of evidence.