A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemoglobin Yamagata: hemoglobin variant detected by HbA1c test. | LitMetric

Hemoglobin (Hb) Yamagata is a rare Hb variant, which has been reported only twice-one case each in Japan and Korea. This variant arises from a Lys --> Asn substitution due to a mutation of AAA to AAC or AAT at codon 133 of the beta-globin gene. This study reports the third case of a patient detected with Hb Yamagata [HBB: c.399A>T; p.Lys133Asn] and discusses the effect of this variant on HbA1c measurement. This variant was detected in a 70-yr-old Korean man with diabetes mellitus during a routine follow-up. The HbA1c concentration determined using Variant ll Turbo (Bio-Rad, USA) was abnormally high at 47.9%. It was impossible to measure the HbA1c level accurately using Variant ll Thalassemia Mode (Bio-Rad, USA). However, the HbA1c levels analyzed by HLC-723 G7 (Tosoh, Japan), Cobas Integra (Roche, Switzerland) and NycoCard (Axis-Shield, Norway) were 5.0%, 8.0%, and 7.9%, respectively. This study shows that Hb Yamagata interferes with the accurate measurement of HbA1c levels in a diabetic patient. Taking these findings into consideration, we think that an immunoassay or affinity chromatography can be used as an alternate method for measuring the HbA1c level in a patient with this variant. In conclusion, a patient can be inferred to have an Hb variant if the HbA1c concentration is abnormally high or low or if there is a discrepancy between the results obtained using different methods, and if the clinical status of the patient suggests the presence of abnormal Hb. Subsequently, the HbA1c values can be determined by methods based on different principles.

Download full-text PDF

Source
http://dx.doi.org/10.3343/kjlm.2009.29.6.536DOI Listing

Publication Analysis

Top Keywords

variant
9
hba1c
9
hemoglobin yamagata
8
variant detected
8
variant hba1c
8
hba1c concentration
8
bio-rad usa
8
abnormally high
8
hba1c level
8
hba1c levels
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!