Site comparison of selected aerosol samplers in the wood industry.

Ann Occup Hyg

Institut National de Recherche et de Sécurité, Rue du Morvan, CS 60027, 54519 Vandoeuvre les Nancy Cedex, France.

Published: March 2010

AI Article Synopsis

  • The study evaluated different dust samplers (IOM, CIP 10-I v1, ACCU-CAP, and Button) at wood industry companies using the CALTOOL system, finding little difference in concentration results when compared to the CALTOOL mouth.
  • The sampled dust concentrations indicated that all samplers collected more dust than a closed-face cassette (CFC), with IOM capturing the most dust, approximately double that of the CFC.
  • Published literature shows larger discrepancies between the IOM sampler and CFC than this study, which may be due to variations in the CFC's orientation during sampling.

Article Abstract

Several samplers (IOM, CIP 10-I v1, ACCU-CAP, and Button) were evaluated at various wood industry companies using the CALTOOL system. The results obtained show that compared to the CALTOOL mouth, which can be considered to be representative of the exposure of a person placed at the same location under the same experimental conditions, the concentrations measured by the IOM, CIP 10-I v1, and ACCU-CAP samplers are not significantly different (respectively, 1.12, 0.94, and 0.80 compared to 1.00), the Button sampler (0.86) being close to the ACCU-CAP sampler. Comparisons of dust concentrations measured using both a closed-face cassette (CFC) and one of the above samplers were also made. In all, 235 sampling pairs (sampler + CFC) taken at six companies provided us with a comparison of concentrations measured using IOM, CIP 10-I v1, ACCU-CAP, and Button samplers with concentrations measured using a CFC. All the studied samplers collected systematically more dust than the CFC (2.0 times more for the IOM sampler, 1.84 times more for the CIP 10-I v1 sampler, 1.68 times more for the ACCU-CAP sampler, and 1.46 times more for the Button sampler). The literature most frequently compares the IOM sampler with the CFC: published results generally show larger differences compared with the CFC than those found during our research. There are several explanations for this difference, one of which involves CFC orientation during sampling. It has been shown that concentrations measured using a CFC are dependent on its orientation. Different CFC positions from one sampling session to another are therefore likely to cause differences during CFC-IOM sampler comparisons.

Download full-text PDF

Source
http://dx.doi.org/10.1093/annhyg/mep078DOI Listing

Publication Analysis

Top Keywords

concentrations measured
20
cip 10-i
16
iom cip
12
10-i accu-cap
12
sampler
9
cfc
9
wood industry
8
accu-cap button
8
measured iom
8
button sampler
8

Similar Publications

Background: Clonal myeloproliferation and fibrotic transformation of the bone marrow (BM) are the pathogenetic events most commonly occurring in myelofibrosis (MF). There is great evidence indicating that tumor microenvironment is characterized by high lactate levels, acting not only as an energetic source, but also as a signaling molecule.

Methods: To test the involvement of lactate in MF milieu transformation, we measured its levels in MF patients' sera, eventually finding a massive accumulation of this metabolite, which we showed to promote the expansion of immunosuppressive subsets.

View Article and Find Full Text PDF

Association between Mediterranean diet and metabolic health status among adults was not mediated through serum adropin levels.

BMC Public Health

January 2025

Department of Community Nutrition, School of Nutrition and Food Science, Nutrition and Food Security Research Center, Isfahan University of Medical Sciences, PO Box 81745-151, Isfahan, Iran.

Background: Prevalence of metabolic disorders has been increased in recent years around the world. The relationship between Mediterranean diet (MD) with metabolic health status and serum adropin levels has been less examined in Iranian adults. We investigated the association between MD compliance with metabolic health status and adropin hormone in Iranian adults.

View Article and Find Full Text PDF

Background: Rhabdomyolysis is frequently associated with acute kidney injury (AKI). Due to the nephrotoxic properties of myoglobin, its rapid removal is relevant. If kidney replacement therapy (KRT) is necessary for AKI, a procedure with effective myoglobin elimination should be preferred.

View Article and Find Full Text PDF

2-[F]Fluoropropionic Acid PET Imaging of Doxorubicin-Induced Cardiotoxicity.

Mol Imaging Biol

January 2025

Department of Radiology, Weill Cornell Medicine, 413 E 69th Street, Room BB-1604, New York, NY, 10021, USA.

Purpose: Treatment of pediatric cancers with doxorubicin is a common and predictable cause of cardiomyopathy. Early diagnosis of treatment-induced cardiotoxicity and intervention are major determinants for the prevention of advanced disease. The onset of cardiomyopathies is often accompanied by profound changes in lipid metabolism, including an enhanced uptake of short-chain fatty acids (SCFA).

View Article and Find Full Text PDF

Background: Neurological dysfunction is a common complication of traumatic brain injury (TBI), and early treatments are critical for the long-term prognosis. This study aimed to investigate whether hypidone hydrochloride (YL-0919) improves neurological function impairment in mice with TBI.

Methods: TBI was induced in adult male C57BL/6J mice using the controlled cortical impact (CCI) method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!