Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Some G-quadruplex-hemin complexes are DNAzyme peroxidases that efficiently catalyze H(2)O(2)-mediated reactions, such as the oxidation of ABTS (2,2'-azinobis(3-ethylbenzothiozoline)-6-sulfonic acid) by H(2)O(2). Since Ag(+) chelates guanine bases at the binding sites are involved in G-quadruplex formation, the presence of Ag(+) may disrupt these structures and inhibit the peroxidase activity of G-quadruplex-hemin DNAzymes. On the basis of this principle, a highly sensitive and selective Ag(+)-detection method was developed. The method allows simple detection of aqueous Ag(+) with a detection limit of 64 nM and a linear range of 50-3000 nM. Cysteine (Cys) is a strong Ag(+)-binder and competes with quadruplex-forming G-rich oligonucleotides for Ag(+)-binding, promoting the reformation of G-quadruplexes and increasing their peroxidase activity. Therefore, the Ag(+)-sensing system was also developed as a Cys-sensing system. This "turn-on" process allowed the detection of Cys at concentrations as low as 50 nM using a simple colorimetric technique. The Cys-sensing system could also be used for the detection of reduced glutathione (GSH). Neither the Ag(+)-sensing nor the Cys-sensing systems required labeled oligonucleotides. In addition, both gave large changes in absorbance signal that could be observed by the naked eye. Thus, a simple visual method for Ag(+)- or Cys-detection was developed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac902421u | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!