Objective: We present herein a novel algorithm for architectural distortion detection that utilizes the point convergence index with the likelihood of lines (e.g., spiculations) relating to architectural distortion.

Materials And Methods: Validation was performed using 25 computed radiography (CR) mammograms, each of which has an architectural distortion with radiating spiculations. The proposed method comprises five steps. First, the lines were extracted on mammograms, such as spiculations of architectural distortion as well as lines in the mammary gland. Second, the likelihood of spiculation for each extracted line was calculated. In the third step, point convergence index weighted by this likelihood was evaluated at each pixel to enhance distortion only. Fourth, local maxima of the index were extracted as candidates for the distortion, then classified based on nine features in the last step.

Results: Point convergence index without the proposed likelihood generated 84.48/image false-positives (FPs) on average. Conversely, the proposed index succeeded in decreasing this number to 12.48/image on average when sensitivity was 100%. After the classification step, number of FPs was reduced to 0.80/image with 80.0% sensitivity.

Conclusion: Combination of the likelihood of lines with point convergence index is effective in extracting architectural distortion with radiating spiculations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-008-0267-9DOI Listing

Publication Analysis

Top Keywords

architectural distortion
20
point convergence
16
distortion detection
8
likelihood lines
8
distortion radiating
8
radiating spiculations
8
distortion
7
architectural
6
likelihood
5
pilot study
4

Similar Publications

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Phase-contrast micro-tomography ([Formula: see text]CT) with synchrotron radiation can aid in the differentiation of subtle density variations in weakly absorbing soft tissue specimens. Modulation-based imaging (MBI) extracts phase information from the distortion of reference patterns, generated by periodic or randomly structured wavefront markers (e.g.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

Sensitive detection of formaldehyde a luminescent distorted EuL tetrahedral cage.

Chem Commun (Camb)

January 2025

College of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.

A distorted low-symmetry EuL tetrahedral cage was fabricated through the self-assembly of europium ions and -symmetric bowl-shaped ligands containing a phosphangulene core. X-ray crystallography confirmed its unique architecture, featuring significant structural distortion and solvent-accessible coordination sites. This cage showcases exceptional luminescence-based sensitivity for formaldehyde detection compared to other analogs, achieving an impressive detection limit of 19.

View Article and Find Full Text PDF

Cobalt-based oxides have attracted significant attention as p-type thermoelectric materials due to their wide operational temperature range. However, their low average figure of merit () value has hindered service performance. A series of cation vacancies as Ca-active sites were introduced into CaCoO (0 ≤ ≤ 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!