Purpose: To discuss an approach to improve education in C-arm operation and reduction of radiation hazards based on a computer based training and simulation system called virtX.
Methods: virtX is equipped with a visualization of scattered radiation and means to include patient positioning changes in radiograph simulation. virtX was integrated in a course for ORP and evaluated based on questionnaires.
Results: Response rate was 73 (n = 77), mean age 35.4 (+/-9.2) and professional experience 11.2+/- 10.4 years. 91% use a C-arm regularly, 8% casually and 1% not. 78% agree that the translation of patient dummy positioning changes to simulated X-ray images is sufficiently realistic, 1% disagree (neutral 17%). 79% state that they acquired new knowledge concerning avoiding unnecessary radiation exposure, 10% do not (neutral 11%).
Conclusions: The virtX-approach of simulating radiograph generation including patient positioning and scattered radiation was evaluated positively concerning its suitability for imparting knowledge regarding radiation protection and C-arm operation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-009-0322-1 | DOI Listing |
Global Spine J
January 2025
Department of Neurosurgery, Faculty of Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria.
BMC Musculoskelet Disord
January 2025
Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, People's Republic of China.
Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.
Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.
Eur J Radiol
January 2025
Department of Stereotactic and Functional Neurosurgery, Medical Center - University of Freiburg, Faculty of Medicine, 79106 Freiburg, Germany; Fraunhofer Institute for Laser Technology (ILT), 52074 Aachen, Germany.
Purpose: Directional deep brain stimulation (dDBS) relies on electrodes steering the stimulation field in a specific direction. Post implantation, however, the intended and real orientation of the lead frequently deviates e.g.
View Article and Find Full Text PDFWorld J Urol
January 2025
Department of Urology, Beijing Jishuitan Hospital, Capital Medical University, Beijing, 102208, China.
Purpose: The objective of this study was to explore the feasibility of using the TianJi Robot system for navigated needle positioning in the PCNL procedure in vitro.
Methods: A pig kidney with a segment of ureter was selected as the in vitro organ model. Iodine contrast agent was infused into the renal pelvis to dilate the renal pelvis and calyx to establish the in vitro hydronephrosis model.
J Bronchology Interv Pulmonol
April 2025
Thoracic Surgery, BASS Medical Group, Walnut Creek, CA.
Background: This study aimed to quantify radiation doses during navigational bronchoscopy procedures, comparing them with reported cohorts and evaluating the LungVision (Body Vision Medical Inc.) system's efficacy in dose reduction.
Methods: This retrospective observational study included 52 consecutive navigational bronchoscopy cases, categorized into 4 imaging groups based on the C-arm: Cios Spin (Siemens Healthineers), or OEC 9900 (GE HealthCare); and the 3D tomographic imaging algorithm: Cios Spin's onboard imaging, or LungVision's AI-driven imaging.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!