Purpose: To test the ability of MION-47 enhanced MRI to identify tissue macrophage infiltration in a rabbit model of aortic valve sclerosis (AVS).

Materials And Methods: The aortic valves of control and cholesterol-fed New Zealand White rabbits were imaged in vivo pre- and 48 h post-intravenous administration of MION-47 using a 1.5 Tesla (T) MR clinical scanner and a CINE fSPGR sequence. MION-47 aortic valve cusps were imaged ex vivo on a 3.0T whole-body MR system with a custom gradient insert coil and a three-dimensional (3D) FIESTA sequence and compared with aortic valve cusps from control and cholesterol-fed contrast-free rabbits. Histopathological analysis was performed to determine the site of iron oxide uptake.

Results: MION-47 enhanced the visibility of both control and cholesterol-fed rabbit valves in in vivo images. Ex vivo image analysis confirmed the presence of significant signal voids in contrast-administered aortic valves. Signal voids were not observed in contrast-free valve cusps. In MION-47 administered rabbits, histopathological analysis revealed iron staining not only in fibrosal macrophages of cholesterol-fed valves but also in myofibroblasts from control and cholesterol-fed valves.

Conclusion: Although iron oxide labeling of macrophage infiltration in AVS has the potential to detect the disease process early, a macrophage-specific iron compound rather than passive targeting may be required.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5638659PMC
http://dx.doi.org/10.1002/jmri.22008DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
control cholesterol-fed
16
iron oxide
12
valve cusps
12
valve sclerosis
8
enhanced mri
8
mion-47 enhanced
8
macrophage infiltration
8
aortic valves
8
imaged vivo
8

Similar Publications

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Lower mini-sternotomy: an approach for treating all valvulopathies?

Ann Thorac Surg

December 2024

Sorbonne University, Department of Cardiovascular and Thoracic Surgery, Institute of Cardiology, Pitié-Salpêtrière Hospital, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.

Background: Lower mini-sternotomy offers the advantage of providing excellent visualization of the 4 cardiac cavities, allowing surgical treatment of aortic, mitral and tricuspid valves as well as any intra-cavitary procedure. Technical issues, as well as safety and echocardiographic results of this approach, are lacking. The aim of this retrospective study was to describe outcomes of lower mini-sternotomy to treat valvulopathies and other intracardiac surgeries.

View Article and Find Full Text PDF

Is connective tissue disorder a risk factor for durability after valve-sparing root replacement?

Semin Thorac Cardiovasc Surg

December 2024

Aortic Center, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:

View Article and Find Full Text PDF

Background: Interleaflet haemorrhage (IH) plays a well-recognized detrimental role in calcified aortic valve disease (CAVD). However, IH-induced fibro-osteogenic responses in valvular interstitial cells (VICs) appear to be triggered under specific pathological conditions. Iron deficiency (ID), a common co-morbidity in CAVD, may influence these responses.

View Article and Find Full Text PDF

Aortitis, defined as inflammation of the aorta, can lead to aneurysms and dissections. Intra-operative sampling is essential for diagnosis, with many cases presenting asymptomatically as clinically isolated aortitis. Previous studies investigating aortitis in major aortic surgery have been limited by low intra-operative sampling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!