A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of Knight-Taylor brace on balance performance in osteoporotic patients with vertebral compression fracture. | LitMetric

Effects of Knight-Taylor brace on balance performance in osteoporotic patients with vertebral compression fracture.

J Back Musculoskelet Rehabil

Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital-Kaohsiung Medical Center, Chang Gung University College of Medicine, Kaohsiung, Taiwan.

Published: April 2010

Objective: To assess the changes in static and dynamic balance and movement strategies in patients with severe osteoporotic vertebral compression fracture while wearing and not wearing the Knight-Taylor (K-T) spinal brace.

Subjects: 47 patients with severe osteoporotic vertebral compression fracture, which was confirmed on radiographs and with bone density measurements obtained by dual energy X-ray absorption.

Intervention: Patients were randomly subjected to computerized dynamic posturography, which contained sensory organization tests, motor control balance test at 75% limit of stability (LOS) in 8 movement directions, and left/right rhythmic weight shift test (L/R RWS), while wearing and not wearing the K-T spinal brace, respectively.

Results: Patients wearing the spinal brace had significantly increased average stability, significantly increased average maximal stability under the swayed vision with fixed support surface condition and under the eye open with swayed support surface condition, significantly increased ankle strategy and decreased average velocity of COG target sway under the eye open with swayed support surface condition, significantly reduced the frequency of falls under the eye closed with swayed support surface condition and swayed vision with swayed support surface condition, and significantly decreased in the percentage of directional control with no difference of reaction time in the LOS test, and an increase in the on-axis velocity in the L/R RWS test.

Conclusions: The K-T spinal brace efficiently enables the subjects to maintain static and dynamic motor balance. Its use decreases the fall frequency but limits the directional control in severe osteoporotic patients with vertebral compression fracture.

Download full-text PDF

Source
http://dx.doi.org/10.3233/BMR-2009-0218DOI Listing

Publication Analysis

Top Keywords

support surface
20
surface condition
20
vertebral compression
16
compression fracture
16
swayed support
16
severe osteoporotic
12
k-t spinal
12
spinal brace
12
osteoporotic patients
8
patients vertebral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!