The 2D ionization chamber array I'mRT MatriXX (IBA, Schwarzenbruck, Germany) has been developed for absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT) for perpendicular beam incidence. The aim of this study is to evaluate the applicability of I'mRT MatriXX for oblique beam incidence and hybrid plan verification of IMRT with original gantry angles. For the assessment of angular dependence, open fields with gantry angles in steps of 10 degrees were calculated on a CT scan of I'mRT MatriXX. For hybrid plan verification, 17 clinical IMRT plans and one rotational plan were used. Calculations were performed with pencil beam (PB), collapsed cone (CC) and Monte Carlo (MC) methods, which had been previously validated. Measurements were conducted on an Elekta SynergyS linear accelerator. To assess the potential and limitations of the system, gamma evaluation was performed with different dose tolerances and distances to agreement. Hybrid plan verification passed the gamma test with 4% dose tolerance and 3 mm distance to agreement in all cases, in 82-88% of the cases for tolerances of 3%/3 mm, and in 59-76% of the cases if 3%/2 mm were used. Separate evaluation of the low dose and high dose regions showed that I'mRT MatriXX can be used for hybrid plan verification of IMRT plans within 3% dose tolerance and 3 mm distance to agreement with a relaxed dose tolerance of 4% in the low dose region outside the multileaf collimator (MLC).

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/55/2/N02DOI Listing

Publication Analysis

Top Keywords

hybrid plan
20
plan verification
20
i'mrt matrixx
16
dose tolerance
12
verification intensity-modulated
8
intensity-modulated radiation
8
radiation therapy
8
therapy imrt
8
ionization chamber
8
chamber array
8

Similar Publications

Photonics bound states in the continuum (BICs) are peculiar localized states in the continuum of free-space waves, unaffected by far-field radiation loss. Although plasmonic nano-antennas squeeze the optical field to nanoscale volumes, engineering the emergence of quasi-BICs with plasmonic hotspots remains challenging. Here, the origin of symmetry-protected (SP) quasi-BICs in a 2D system of silver-filled dimers, quasi-embedded in a high-index dielectric waveguide, is investigated through the strong coupling between photonic and plasmonic modes.

View Article and Find Full Text PDF

Background: The aim of this study was to investigate whether the hybrid technique yields superior outcomes in comparison with the total arch replacement combined with frozen elephant trunk (TAR + FET) for acute aortic dissection (AAD) involving the aortic arch.

Methods: This retrospective cohort study using propensity-score matching included patients with AAD involving the aortic arch admitted to Nanjing First Hospital and Shanghai General Hospital from January 2015 to June 2020. The in-hospital and mid-term outcomes were compared between patients who received hybrid treatment (n = 136) and those who received TAR + FET (n = 415).

View Article and Find Full Text PDF

This paper deals with a "digital twin" (DT) approach for processing, reprocessing, and scrapping (P/R/S) technology running on a modular production system (MPS) assisted by a mobile cyber-physical robotic system (MCPRS). The main hardware architecture consists of four line-shaped workstations (WSs), a wheeled mobile robot (WMR) equipped with a robotic manipulator (RM) and a mobile visual servoing system (MVSS) mounted on the end effector. The system architecture integrates a hierarchical control system where each of the four WSs, in the MPS, is controlled by a Programable Logic Controller (PLC), all connected via Profibus DP to a central PLC.

View Article and Find Full Text PDF

The Management of the Aortic Arch in Type A Aortic Dissection: Replace, Repair with the AMDS, or Leave for Another Day?

J Cardiovasc Dev Dis

January 2025

Division of Cardiac Surgery, Department of Surgery, University of Alberta, Edmonton, AB T6G 2R3, Canada.

Objectives: Acute type A aortic dissection (ATAAD) is a life-threatening condition that requires emergent surgical intervention. Numerous surgical approaches exist for ATAAD, and controversy remains regarding the optimal arch interventions for ATAAD patients. Aortic Arch Interventions: Approaches to ATAAD repair include hemiarch repair or extended arch repairs, including the hemiarch with a hybrid stent implantation, such as the AMDS hybrid Prosthesis, total arch replacement (TAR), and the use of an elephant trunk and frozen elephant trunk.

View Article and Find Full Text PDF

The cyclic stability of aqueous zinc-manganese batteries (ZMBs) is greatly restricted by the side reaction of the anode and the irreversibility of the cathode. In this work, a solid-liquid hybrid electrolyte mixing by traditional ZnSO-based electrolyte and diatomite (denoted as Dtm) is proposed that exhibits good compatibility and reversibility in both the anode interface and the cathode interface. The abundant hydroxyl groups at the anode interface disturb the hydrogen bond network of water molecule, which weakens the corrosion of the active water to Zn anode.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!