A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios. | LitMetric

The characteristic depressed hemodynamic state and gradually declining circulatory function in Fontan patients necessitates alternative postoperative management strategies incorporating a system level approach. In this study, the single-ventricle Fontan circulation is modeled by constructing a practical in vitro bench-top pulsatile pediatric flow loop which demonstrates the ability to simulate a wide range of clinical scenarios. The aim of this study is to illustrate the utility of a novel single-ventricle flow loop to study mechanical cardiac assist to Fontan circulation to aid postoperative management and clinical decision-making of single ventricle patients. Two different pediatric ventricular assist devices, Medos and Pediaflow Gen-0, are anastomosed in two nontraditional configurations: systemic venous booster (SVB) and pulmonary arterial booster (PAB). Optimum ventricle assist device strategy is analyzed under normal and pathological (pulmonary hypertension) conditions. Our findings indicate that the Medos ventricular assist device in SVB configuration provided the highest increase in pulmonary (46%) and systemic (90%) venous flow under normal conditions, whereas for the hypertensive condition, highest pulmonary (28%) and systemic (55%) venous flow augmentation were observed for the Pediaflow ventricular assist device inserted as a PAB. We conclude that mechanical cardiac assist in the Fontan circulation effectively results in flow augmentation and introduces various control modalities that can facilitate patient management. Assisted circulation therapies targeting single-ventricle circuits should consider disease state specific physiology and hemodynamics on the optimal configuration decisions.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2009.00951.xDOI Listing

Publication Analysis

Top Keywords

fontan circulation
12
ventricular assist
12
assist device
12
postoperative management
8
flow loop
8
mechanical cardiac
8
cardiac assist
8
assist fontan
8
venous flow
8
flow augmentation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!