In vitro evaluation of the potential of a circulatory-assist device to damage blood cells has generally been performed using blood from various species. Problems with this approach include the variability of blood sensitivity to mechanical stress in different species, preparation of blood including the adjustment of hematocrit to a standard value, changes in the mechanical properties of blood that occur during storage, and necessity to pool blood samples to obtain an adequate amount of blood for in vitro circulating systems. We investigated whether the mechanical degradation of a drag-reducing polymer (DRP) solution resulting in the loss of drag-reducing ability can indicate the degree of shear-induced blood damage within blood pumps. DRP solution (polyethylene oxide, 4,500 kDa, 1,000 ppm) or porcine blood were driven through a turbulent flow system by a centrifugal pump, either the Bio-Pump BPX-80 (Medtronic, Inc.) or CentriMag (Levitronix LLC) at a constant pressure gradient of 300 mm Hg for 120 minutes. DRP mechanical degradation was evaluated by reduction of flow rate and solution viscosity. A proposed index of DRP mechanical degradation (PDI) is similar to the normalized index of hemolysis (NIH) typically used to quantify the results of in vitro testing of blood pumps. Results indicate that the mechanical degradation of DRP solutions may provide a sensitive standard method for the evaluation of potential blood trauma produced by blood pumps without the use of blood.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3026831PMC
http://dx.doi.org/10.1097/MAT.0b013e3181c8e281DOI Listing

Publication Analysis

Top Keywords

blood
16
blood pumps
16
mechanical degradation
16
evaluation potential
12
damage blood
12
drag-reducing polymer
8
vitro evaluation
8
potential blood
8
blood damage
8
drp solution
8

Similar Publications

Prospective validation study of a combined urine and plasma test for predicting high-grade prostate cancer in biopsy naïve men.

Scand J Urol

January 2025

Department of Urology, Odense University Hospital, Odense, Denmark; Academy of Geriatric Cancer Research (AgeCare), Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.

Objective: Early and accurate diagnosis of prostate cancer (PC) is crucial for effective treatment. Diagnosing  clinically insignificant cancers can lead to overdiagnosis and overtreatment, highlighting the importance of accurately selecting patients for further evaluation based on improved risk prediction tools. Novel biomarkers offer promise for enhancing this diagnostic process.

View Article and Find Full Text PDF

Introduction: Many patients acutely self-poisoned with organophosphorus insecticides have co-ingested ethanol. Currently, profenofos 50% emulsifiable concentrate (EC50) is commonly ingested for self-harm in Sri Lanka. Clinical experience suggests that ethanol co-ingestion makes management more difficult.

View Article and Find Full Text PDF

Glucose Transporter 1 Deficiency Impairs Glucose Metabolism and Barrier Induction in Human Induced Pluripotent Stem Cell-Derived Astrocytes.

J Cell Physiol

January 2025

Department of Pharmaceutical Sciences and Center for Blood-Brain Barrier Research, Jerry H. Hodge School of Pharmacy, Texas Tech University Health Sciences Center, Amarillo, Texas, USA.

Glucose is a major source of energy for the brain. At the blood-brain barrier (BBB), glucose uptake is facilitated by glucose transporter 1 (GLUT1). GLUT1 Deficiency Syndrome (GLUT1DS), a haploinsufficiency affecting SLC2A1, reduces glucose brain uptake.

View Article and Find Full Text PDF

Background: The search for early and minimally invasive diagnostic approaches to pancreatic cancer (PC) remains an important issue. One of the most promising directions is to find a sensitive key in the metabolic changes during widespread causes of PC, i.e.

View Article and Find Full Text PDF

Deficient Mismatch Repair and BRAF Mutations in Metastatic Colorectal Cancer in the South Island of New Zealand.

Asia Pac J Clin Oncol

January 2025

Wellington Blood and Cancer Centre, Health New Zealand/Te Whatu Ora - Capital, Coast and Hutt Valley, Wellington, New Zealand.

Aim: Manatū Hauora, the Ministry of Health of New Zealand (NZ), published minimum standards for molecular testing of colorectal cancers (CRCs) in June 2018. These included mismatch repair (MMR) testing at diagnosis and BRAFV600E mutation analysis on newly diagnosed stage IV CRCs. This study aimed to determine the proportion of patients with CRC in the South Island of NZ with metastatic deficient mismatch repair (dMMR) CRC, the proportion of metastatic CRCs and dMMR CRCs that have a BRAFV600E mutation, and audit testing for BRAF mutations and appropriate referral to genetics services.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!