Purpose: To prospectively determine whether cardiac-gated multidetector computed tomography (CT) allows visualization of aortic valve leaflets after bioprosthetic aortic valve replacement (AVR), to provide an accurate method for measuring the aortic valve opening, and to provide morphologic and functional information regarding the mechanism underlying poor function of the bioprosthetic valve.

Materials And Methods: The institutional review board approved the study protocol; informed consent was given. Fifty-four patients (27 men; mean age, 75 years + or - 8 [standard deviation]) with bioprosthetic AVR implanted 2 years + or - 3 earlier underwent 64-section CT and transthoracic echocardiography (TTE). Two blinded observers manually planimetered the aortic valve area (AVA) by using a computer workstation on end-systolic short-axis CT images and measured opening angles (OAs) between the bioprosthesis annulus base and the free margin on long-axis images. These measurements were compared with those of the effective orifice area (EOA) of the valve at Doppler continuity-equation TTE by using regression and Bland-Altman methods. Morphology and mobility of leaflets in normally functioning (EOA indexed to body surface area [EOA(i)] > 0.65 cm(2)/m(2)) and dysfunctional (EOA(i)< 0.65 cm(2)/m(2)) AVRs were compared.

Results: AVA at CT correlated highly to EOA at TTE (r = 0.93, P < .001) but was significantly larger (1.2 cm(2) + or - 0.4 vs 1.1 cm(2) + or - 0.3, P < .001) than EOA at TTE. In dysfunctional bioprostheses (n = 34), CT results showed a variety of morphologic abnormalities, such as leaflet thickening (n = 9), presumed thrombotic material (n = 6), and leaflet calcification (n = 1). Multidetector CT results demonstrated restriction of leaflet motion indicated by lower OA (64 degrees + or - 5 vs 79 degrees + or - 3, P < .0001) in dysfunctional AVRs than in normally functioning AVRs (n = 11).

Conclusion: Sixty-four-section CT can help accurately measure AVA in bioprosthetic AVR compared with EOA at TTE. It can also show morphologic abnormalities and reduced leaflet motion in a dysfunctional bioprosthesis, thereby potentially unraveling the mechanism of dysfunction.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.0000082294DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
eoa tte
12
valve opening
8
transthoracic echocardiography
8
bioprosthetic avr
8
065 cm2/m2
8
morphologic abnormalities
8
leaflet motion
8
valve
7
leaflet
5

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Previous studies evaluated the prognostic role of hematological parameters in predicting outcome in patients with infective endocarditis (IE). However, only a few studies evaluated the role of hematological parameters in patients undergoing surgery for IE. The aim of this study was to review our 20-year experience with the treatment of native (NVE) and prosthetic (PVE) valve endocarditis and to evaluate the role of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-to monocyte ratio (NMR), and systemic inflammatory index (SII) on early and long-term outcomes of patients undergoing surgery for NVE and PVE.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!