Dynamic interconversion of chiral oxime compounds in gas chromatography.

J Chromatogr A

School of Applied Sciences, RMIT University, GPO Box 2476V, Melbourne, Victoria 3001, Australia.

Published: February 2010

A number of chiral oxime compounds have been synthesised and their gas chromatographic analysis on both a polyethelene glycol phase column and two chiral column phases was investigated. Of particular interest to this work is the observation of dynamic interconversion behaviour, both in a single dimensional analysis, and by using comprehensive two-dimensional gas chromatography (GCxGC). A number of non-chiral compounds were studied as a means to understand the nature of the behaviour observed. As expected, the achiral compound on both the wax column and the chiral column generated two isomeric compounds-the E and Z isomers. On the wax column, a characteristic interconversion zone representing the dynamic process was observed, with extent of interconversion dependent on the conditions used. For the chiral compounds, two isomers and the interconversion zone were exhibited on the wax column, however on the chiral column 4 isomeric peaks were found-the (R) and (S) enantiomers of each of the E and Z isomers. In the case of the chiral column, the extent of interconversion was negligible, and this appears to correlate with the use of low polarity columns. In order to encourage dynamic interconversion, a polyethylene glycol column was coupled to the chiral column, by placing it either before or after the chiral column. In this case a monitor detector was employed between the two columns in order to isolate the effects of the first column from the behaviour on the second. In a further study, the most appropriate column arrangement from the earlier study was placed into a comprehensive two-dimensional gas chromatography instrument, with a wax-phase column in the second dimension. The unique location of peaks for each of the molecules in 2D space and patterns for the interconversion processes is interpreted phenomenologically.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2009.11.084DOI Listing

Publication Analysis

Top Keywords

chiral column
24
column
14
dynamic interconversion
12
gas chromatography
12
column chiral
12
wax column
12
chiral
9
chiral oxime
8
oxime compounds
8
comprehensive two-dimensional
8

Similar Publications

Evodiamine, a chiral quinazoline alkaloid in the traditional Chinese medicine Evodiae fructus, exhibited efficacy for CNS diseases. In this study, the pure enantiomers of evodiamine were prepared in large quantities via chemical resolution. Their structures were elucidated by MS, NMR and ECD.

View Article and Find Full Text PDF

In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.

View Article and Find Full Text PDF

Computer simulation was utilized to characterize the electrophoretic processes occurring during the enantioselective capillary electrophoresis-mass spectrometry (CE-MS) analysis of ketamine, norketamine, and hydroxynorketamine in a system with partial filling of the capillary with 19 mM (equals 5%) of highly sulfated γ-cyclodextrin (HS-γ-CD) and analyte detection on the cathodic side. Provided that the sample is applied without or with a small amount of the chiral selector, analytes become quickly focused and separated in the thereby formed HS-γ-CD gradient at the cathodic end of the sample compartment. This gradient broadens with time, remains stationary, and gradually reduces its span from the lower side due to diffusion such that analytes with high affinity to the anionic selector become released onto the other side of the focusing gradient where anionic migration and defocusing occur concomitantly.

View Article and Find Full Text PDF

Efficient enantioselective separation is a critical process in pharmaceutical and chemical industries for the production of chiral compounds. Herein, we developed a novel approach for the efficient enantioselective separation of primary amines using supercritical fluid chromatography (SFC) with a commercially available SFC column, Cel1. The key factors of separation, including cosolvent ratios, total cosolvent percentages, and temperature, were systematically assessed in this study.

View Article and Find Full Text PDF

Background: Isotopologues resulting from the labelling of molecules with deuterium have attracted interest due to the isotope effect observed in chemistry and biosciences. Isotope effect may also play out in noncovalent interactions and mechanisms leading to intermolecular recognition. In chromatography, differences in retention time between isotopologues, as well as between isotopomers have been observed resulting in two different elution sequences (isotope effects): the normal isotope effect when heavier isotopologues retain longer than lighter analogues, and the inverse isotope effect featuring the opposite elution order.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!