STUDY DESIGN.: A prospective interventional case-series study plus a retrospective analysis of historical patients for comparison of data. OBJECTIVE.: To evaluate workflow, feasibility, and clinical outcome of navigated stabilization procedures with data acquisition by intraoperative computed tomography. SUMMARY OF BACKGROUND DATA.: Routine fluoroscopy to assess pedicle screw placement is not consistently reliable. Our hypothesis was that image-guided spinal navigation using an intraoperative CT-scanner can improve the safety and precision of spinal stabilization surgery. METHODS.: CT data of 94 patients (thoracolumbar [n = 66], C1/2 [n = 12], cervicothoracic instability [n = 16]) were acquired after positioning the patient in the final surgical position. A sliding gantry 40-slice CT was used for image acquisition. Data were imported to a frameless infrared-based neuronavigation workstation. Intraoperative CT was obtained to assess the accuracy of instrumentation and, if necessary, the extent of decompression. All patients were clinically evaluated by Odom-criteria after surgery and after 3 months. RESULTS.: Computed accuracy of the navigation system reached <2 mm (0.95 +/- 0.3 mm) in all cases. Additional time necessary for the preoperative image acquisition including data transfer was 14 +/- 5 minutes. The duration of interrupting the surgical process for iCT until resumption of surgery was 9 +/- 2.5 minutes. Control-iCT revealed incorrect screw position >/=2 mm without persistent neurologic or vascular damage in 20/414 screws (4.8%) leading to immediate correction of 10 screws (2.4%). Control-iCT changed the course of surgery in 8 cases (8.5% of all patients). The overall revision rate was 8.5% (4 wound revisions, 2 CSF fistulas, and 2 epidural hematomas). There was no reoperation due to implant malposition. According to Odom-criteria all patients experienced a clinical improvement. A retrospective analysis of 182 patients with navigated thoracolumbar transpedicular stabilizations in the preiCT era revealed an overall revision rate of 10.4% with 4.4% of patients requiring screw revision. CONCLUSION.: Intraoperative CT in combination with neuronavigation provides high accuracy of screw placement and thus safety for patients undergoing spinal stabilization. Reoperations due to implant malpositions could be completely avoided. The system can be installed into a pre-existing operating environment without need for special surgical instruments. The procedure is rapid and easy to perform without restricted access to the patient and-by replacing pre- and postoperative imaging-is not associated with an additional exposure to radiation. Multidisciplinary use increases utilization of the system and thus improves cost-efficiency relation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0b013e3181b77b19 | DOI Listing |
J Int Med Res
January 2025
Department of Orthopaedics, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine; Key Laboratory of Musculoskeletal System Degeneration and Regeneration Translational Research of Zhejiang Province, Hangzhou, China.
An 18-year-old female patient presented with a 1-month history of low back pain, which had worsened and was accompanied by radiating pain in the right lower limb for half a month. She was admitted to our hospital with computed tomography and magnetic resonance imaging findings suggesting calcification of the L3/4 disc and a large intraspinal mass at the L2-4 level. The patient's symptoms did not improve with conservative treatment, and her muscle strength rapidly declined.
View Article and Find Full Text PDFCase Rep Womens Health
March 2025
Sakai City Medical Center, 1-1-1, Ebaraji-cho, Nishi-ku, Sakai, Osaka 593-8304, Japan.
Intramural pregnancy (IMP) is an extremely rare form of ectopic pregnancy (EP), typically associated with previous uterine trauma, adenomyosis, or assisted reproductive technology (ART), such as embryo transfer (ET). Despite its potentially life-threatening nature, the absence of definitive preoperative diagnostic criteria for IMP complicates its early detection and management, especially in patients without known risk factors. Additionally, management becomes more challenging when there is an elevated risk of hemorrhage.
View Article and Find Full Text PDFClin Park Relat Disord
January 2025
Department of Neurology, University Medical Centre Ljubljana, 1000 Ljubljana, Slovenia.
Introduction: Intraoperative microelectrode recording (MER) and intraoperative test stimulation may provide vital information for optimal electrode placement and clinical outcome in movement disorders patients treated with deep brain stimulation (DBS). The aims of this retrospective study were to determine (i) how often the planned (imaging based) placements of electrodes were changed due to MER and intraoperative test stimulation in Parkinson's disease (PD), dystonia and essential tremor (ET) patients; (ii) whether the frequency of repositioning changed over time; (iii) whether patients' age or disease duration (in PD) influenced the frequency of repositioning.
Methods: Data on the planned and the final placement of 141 electrodes in 72 consecutive DBS treated patients (52 PD, 11 dystonia, 9 ET) was collected over the first 8 years of DBS implementation in a single center.
J Dent
January 2025
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:
Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.
Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.
BMC Res Notes
January 2025
Department of Orthopaedic Surgery, Chiba GEKA-NAIKA Hospital, 4-41 Haramachi, Kawaguchi, Saitama, 332-0025, Japan.
Objective: This study aimed to clarify the relationship between the directions of humeral head translation, the presence of acromial or coracoid spurs, and the locations of tendon tears in massive rotator cuff tears. Thirty shoulders from thirty patients with massive rotator cuff tears who underwent reverse shoulder arthroplasty were included. Preoperative 3DCT classified humeral head translation into three groups: minimal type, posterosuperior type, and anterosuperior type.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!