A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical determination of NADH and ethanol based on ionic liquid-functionalized graphene. | LitMetric

Electrochemical determination of NADH and ethanol based on ionic liquid-functionalized graphene.

Biosens Bioelectron

State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, PR China.

Published: February 2010

It is firstly reported that low-potential NADH detection and biosensing for ethanol are achieved at an ionic liquid-functionalized graphene (IL-graphene) modified electrode. A substantial decrease (440 mV) in the overvoltage of the NADH oxidation was observed using IL-graphene/chitosan coating, with oxidation starting at ca. 0 V (vs. Ag|AgCl). And the NADH amperometric response at such a modified electrode is more stable (95.4% and 90% of the initial activity remaining after 10 min and 30 min at 1 mM NADH solution) than that at bare electrode (68% and 46%). Furthermore, the IL-graphene/chitosan-modified electrode exhibited a good linearity from 0.25 to 2 mM and high sensitivity of 37.43 microA mM(-1)cm(-2). The ability of IL-graphene to promote the electron transfer between NADH and the electrode exhibited a novel and promising biocompatible platform for development of dehydrogenase-based amperometric biosensors. With alcohol dehydrogenase (ADH) as a model, the ADH/IL-graphene/chitosan-modified electrode was constructed through a simple casting method. The resulting biosensor showed rapid and highly sensitive amperometric response to ethanol with a low detection limit (5 microM). Moreover, the proposed biosensor has been used to determine ethanol in real samples and the results were in good agreement with those certified by the supplier.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2009.11.009DOI Listing

Publication Analysis

Top Keywords

ionic liquid-functionalized
8
liquid-functionalized graphene
8
modified electrode
8
amperometric response
8
electrode exhibited
8
nadh
6
electrode
6
electrochemical determination
4
determination nadh
4
ethanol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!