Background Context: Degeneration of the intervertebral disc (IVD) involves structural changes in the annulus fibrosus (AF), which could alter the mechanical forces imposed on the nucleus pulposus (NP) tissue. This could contribute to degenerative changes that occur in the NP.
Purpose: The purpose of the study was to determine whether circumferential constraint affects anabolic and catabolic gene expression, biochemical composition, and mechanical properties of NP tissue.
Study Design: Nucleus pulposus cells were isolated from bovine caudal IVD and allowed to form tissue for a period of two weeks. The effect of no, intermediate, or high circumferential constraint on biochemical composition (cellularity and proteoglycan and collagen synthesis), gene expression, and compressive mechanical properties was evaluated.
Results: Increasing the rigidity of circumferential constraint surrounding in vitro formed NP tissue resulted in decreased gene expression of aggrecan and type II collagen and increased expression of MMP-1 and ADAMTS-5. This was associated with decreased accumulation of extracellular matrix and a deterioration of the compressive mechanical properties of the tissue.
Conclusions: As increased circumferential constraint can have a significant negative effect on the composition and quality of NP tissue and this raises the possibility that the AF may contribute to the degenerative or age-related alterations that occur in the NP. Further study in a functional spinal unit is required to validate this.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.spinee.2009.10.011 | DOI Listing |
Materials (Basel)
July 2024
College of Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
In this paper, low circumferential reciprocating load foot-scale tests were performed on two nontruncated PHC B 600 130 tubular piles with bearing nodes to characterize the damage process and morphology of the specimens and to investigate the load-carrying performance of the members. The test results reveal that under the action of tensile-bending-shear loading, the bearing concrete in the node area buckles and is damaged, the anchored reinforcement in the node area yields, the constraint is weakened, an articulation point is formed, and the node rotational capacity increases. When the embedment depth increases from 200 mm to 300 mm, the ultimate bearing capacities of the positive and negative nodes increase by 31.
View Article and Find Full Text PDFEur J Cardiothorac Surg
July 2024
Emis Platform, Limoges University Hospital, Limoges, France.
Full Circumferential Tracheal Replacement (FCTR) is a surgical challenge, indicated in rare cases of extensive tracheal resection, with no consensus on surgical technique or materials. A systematic review according to PRISMA guidelines was carried out from 2000 to 2022 to identify cases of FCTR, to compare surgical indications, the nature of the tracheal substitutes and their immunological characteristics, surgical replacement techniques and vascularization. Thirty-seven patients, including five children, underwent FCTR surgery using 4 different techniques: thyrotracheal complex allograft (n = 2), aorta (n = 12), autologous surgical reconstruction (n = 19), tissue-engineered decellularized trachea (n = 4).
View Article and Find Full Text PDFHeliyon
March 2024
State Key Laboratory of Bridge Engineering Structural Dynamics and Key Laboratory of Bridge Earthquake Resistance Technology, Chongqing, 400067, China.
There have been many research reports on the reinforcement of small-sized square columns with a cross-section of 200mm-300mm using prestressed carbon fiber-reinforced polymer (CFRP) materials, while there are few studies on piers in bridge and tower columns in cable-stayed bridges with a cross-section of several meters or even tens of meters. The horizontal prestressed steel tendons in the anchorage zone of tower columns in cable-stayed bridge replaced by prestressed CFRP sheets can not only facilitate construction and maintenance, but also have good fatigue resistance. The prestressed CFRP plate is used to reinforce the large-sized tower columns by using a specific device to tension the CFRP plate wrapped around the surface of the members.
View Article and Find Full Text PDFBiomimetics (Basel)
January 2024
Department of Structures, Construction and Graphic Expression, Technical University of Cartagena, 30202 Cartagena, Spain.
JBJS Essent Surg Tech
November 2023
Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
Background: The use of a cemented monoblock dual-mobility implant into a fully porous cup is indicated for patients with acetabular bone loss who have a high risk of postoperative hip instability. Patients undergoing lumbar fusion for sagittal spinal deformities have an increased risk of hip dislocation (7.1%) and should be assessed on sitting and standing radiographs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!