The electrochemical determinations of 4-chlorophenol (4-CP) and 4-nitrophenol (4-NP) by chronoamperometry (CA) and multiple pulsed amperometry (MPA) using expanded graphite-epoxy composite (EG-Epoxy) and rotating spectral graphite disc (SG) electrodes are reported. The electrochemical behaviours of both electrodes in the presence of organics informed about oxidation peak potential and the electrode fouling with organics concentration increasing. Setting up the oxidation peak potential as detection potential, only SG gave good electroanalytical performance using CA. However, by MPA applying both electrodes exhibited the capability to assess electrochemically and quantitatively the pollutants from aqueous solutions. UV spectrometric method detecting 4-CP and 4-NP at lambda=280nm and lambda=398nm wavelength, respectively was used for validation and parallel determinations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2009.07.036 | DOI Listing |
Sleep Breath
January 2025
Department of Pulmonary and Critical Care Medicine, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No.1 Da Hua Road, Dong Dan, Dongcheng District, Beijing, 100730, PR China.
Purpose: To investigate the relationship between obstructive sleep apnea hypopnea syndrome (OSAHS) severity and fat, bone, and muscle indices.
Methods: This study included 102 patients with OSAHS and retrospectively reviewed their physical examination data. All patients underwent polysomnography, body composition analysis, dual-energy X-ray absorptiometry, computed tomography (CT) and blood test.
Nano Converg
January 2025
Bendable Electronics and Sustainable Technologies (BEST) Group, Electrical and Computer Engineering Department, Northeastern University, Boston, MA, 02115, USA.
The intriguing way the receptors in biological skin encode the tactile data has inspired the development of electronic skins (e-skin) with brain-inspired or neuromorphic computing. Starting with local (near sensor) data processing, there is an inherent mechanism in play that helps to scale down the data. This is particularly attractive when one considers the huge data produced by large number of sensors expected in a large area e-skin such as the whole-body skin of a robot.
View Article and Find Full Text PDFUltrasound Obstet Gynecol
January 2025
Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, SAR, China.
Objectives: To compare the maternal hemodynamic profile at 12 + 0 to 15 + 6 weeks' gestation in women who subsequently developed pre-eclampsia (PE) and those who did not, and to assess the screening performance of maternal hemodynamic parameters for PE in combination with the Fetal Medicine Foundation (FMF) triple test, including maternal factors (MF), mean arterial pressure (MAP), uterine artery pulsatility index and placental growth factor.
Methods: This was a prospective case-control study involving Chinese women with a singleton pregnancy who underwent preterm PE screening at 11 + 0 to 13 + 6 weeks' gestation using the FMF triple test, between February 2020 and February 2023. Women identified as being at high risk (≥ 1:100) for preterm PE by the FMF triple test were matched 1:1 with women identified as low risk (< 1:100) for maternal age ± 3 years, maternal weight ± 5 kg and date of screening ± 14 days.
Acta Neurol Belg
January 2025
Department of Pediatrics, Neurology Unit, University of Health Sciences, Ankara Etlik City Hospital, Ankara, Turkey.
Introduction: Zellweger spectrum disorder (ZSD) refers to a group of autosomal recessive genetic disorders that affect multiple organ systems and are predominantly caused by pathogenic variants in PEX genes. ZSD present a wide clinical spectrum, ranging from the most severe form, Zellweger syndrome, to the mildest form, Heimler syndrome.
Case Report: A 14-month-old male patient was brought to our clinic with recent-onset ocular tremors and unsteady gait.
Sci Rep
January 2025
Department of Cardiology, University of Galway, University Road, Galway, H91 TK33, Ireland.
Diffuse coronary artery disease (CAD) impacts the immediate hemodynamic and clinical outcomes of percutaneous coronary intervention (PCI). We evaluated whether the diffuse pattern of CAD derived from angiographic Quantitative flow ratio (QFR) impacts the immediate hemodynamic outcome post-PCI and the medium term predicted vessel-oriented composite endpoint (VOCE). Paired pre-procedure QFRs were assessed in 503 patients and 1022 vessels in the Multivessel TALENT (MVT) trial.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!