A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An anatomical assessment of the supracerebellar midline and paramedian approaches to the inferior colliculus for auditory midbrain implants using a neuronavigation model on cadaveric specimens. | LitMetric

The inferior colliculus (IC) is an alternative site for electrode placement in neural deafness due to its surgical accessibility and its well-known tonotopic stratification. In patients where tumor surgery has already occurred and the cerebellopontine angle contains scar tissue or tumor-remnants, midline and paramedian supracerebellar approaches are alternative routes. They are often avoided due to concerns regarding the venous drainage of the cerebellum, the electrode trajectory and the course of the electrode cable. We studied these surgical routes in five neuronavigated fixed cadaveric specimens. For paramedian and midline approaches, the transverse sinus was exposed 5.8mm on average. A mean of 1.6 cerebellar veins, with an average diameter of 2.0mm, draining to the tentorium were transected to reach the tentorial notch. Only 0.4 arterial branches were met. We conclude that the supracerebellar midline and paramedian approaches provide a good exposure of the IC and offer safe and viable alternative routes to the IC. Additionally, they provide a wider angle of action for optimal electrode placement.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jocn.2009.06.034DOI Listing

Publication Analysis

Top Keywords

midline paramedian
12
supracerebellar midline
8
paramedian approaches
8
inferior colliculus
8
cadaveric specimens
8
electrode placement
8
alternative routes
8
anatomical assessment
4
assessment supracerebellar
4
midline
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!