Formal hepatic arterial flush to preserve the liver graft in living donor liver transplantation (LDLT) is not recommended by most transplant centers because direct cannulation may injure the intima of the hepatic artery. The authors describe a method of retrograde arterial flush of the liver graft without arterial cannulation by hepatic venous outflow occlusion (HVOO) in LDLT. First, we proved no backflow of the hepatic artery without HVOO by portal flush to pig livers. Then we used HVOO on 15 LDLT cases (Group HVOO). The results were compared with those of 24 counterpart LDLT cases (Group non-HVOO) without hepatic artery flush. The two-week posttransplantational liver functions were not different between two groups except that the day-three and day-seven serum bilirubin levels were lower in Group HVOO (day-three total bilirubin: 4.99 +/- 4.04 mg/dl versus 7.65 +/- 4.33 mg/dl, p =.016; day-seven total bilirubin: 5.06 +/- 5.02 mg/dl versus 9.57 +/- 6.09, p =.005). The rates of vascular complications, six-month graft survival, and biliary anastomotic stricture in Group HVOO were 0, 93.3, and 13.3% respectively, which were not different from those of Group non-HVOO. In summary, to avoid intima injury, the retrograde arterial flush of liver graft by HVOO is safe in LDLT. The short-term results showed the effect of decreasing early functional cholestasis but the long-term benefits need further evaluation, especially with regards to biliary anastomotic complications.

Download full-text PDF

Source
http://dx.doi.org/10.3109/08941930903410833DOI Listing

Publication Analysis

Top Keywords

arterial flush
16
liver graft
16
retrograde arterial
12
flush liver
12
hepatic artery
12
group hvoo
12
graft living
8
living donor
8
donor liver
8
liver transplantation
8

Similar Publications

Objectives: To develop a predictive score for the prediction of successful endovascular crossing in femoropopliteal artery chronic total occlusions (CTOs).

Methods: In this retrospective study, 84 patients were divided 70%:30% into a training and a testing cohort. Parameters such as cap morphology, side branches, bridging collaterals, flush occlusion, and length were derived from preprocedural CT angiography.

View Article and Find Full Text PDF

Purpose: The use of surgeon-modified fenestrated endograft to treat a bleeding complication in the common iliac artery.

Technique: An Endurant limb graft was modified on back table in theater after planning the fenestration using a semi-automated centerline. The Endurant stent was planned to land flush at the aortic bifurcation.

View Article and Find Full Text PDF

Passivated hydrogel interface: Armor against foreign body response and inflammation in small-diameter vascular grafts.

Biomaterials

December 2024

Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, 430074, China; NMPA Research Base of Regulatory Science for Medical Devices, Institute of Regulatory Science for Medical Devices, Huazhong University of Science and Technology, Wuhan, 430074, China. Electronic address:

The development of small-diameter vascular grafts (SDVGs) still faces significant challenges, particularly in overcoming blockages within vessels. A key issue is the foreign-body response (FBR) triggered by the implants, which impairs the integration between grafts and native vessels. In this study, we applied an interfacial infiltration strategy to create a stable, hydrophilic, and passivated hydrogel coating on SDVGs.

View Article and Find Full Text PDF

Multidetector-row computed tomographic angiography (angio-CT) aims to achieve optimal opacification of the vascular compartment of interest. The distribution and quality of vascular opacification are influenced by patient-related factors, contrast medium (CM)-related factors, and scanner-related factors. This systematic review evaluates these factors and their effects on contrast enhancement.

View Article and Find Full Text PDF

With increased use of extended criteria liver donors, there is a higher incidence of previously unknown intra-abdominal pathologies, including abdominal aortic aneurysms, which are being accidentally found during organ procurement. These findings often involve technical difficulties that challenge organ procurement teams and potentially put at risk the success of organ retrieval and eventual transplant. In this case report, we present a novel case of a successful liver retrieval from a donor with brain death who was incidentally found to have an infrarenal aortic aneurysm that spared both iliac arteries.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!