In recent years, laser-induced acoustic desorption (LIAD) coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been demonstrated to provide a valuable technique for the analysis of a wide variety of nonvolatile, thermally labile compounds, including analytes that could not previously be analyzed by mass spectrometry. Although FT-ICR instruments are very powerful, they are also large and expensive and, hence, mainly used as research instruments. In contrast, linear quadrupole ion trap (LQIT) mass spectrometers are common due to several qualities that make these instruments attractive for both academic and industrial settings, such as high sensitivity, large dynamic range, and experimental versatility. Further, the relatively small size of the instruments, comparatively low cost, and the lack of a magnetic field provide some distinct advantages over FT-ICR instruments. Hence, we have coupled the LIAD technique with a commercial LQIT, the Thermo Fischer Scientific LTQ mass spectrometer. The LQIT was modified for a LIAD probe by outfitting the removable back plate of the instrument with a 6 in. ConFlat flange (CFF) port, gate valve, and sample lock. Reagent ions were created using the LQIT's atmospheric pressure ionization source and trapped in the mass analyzer for up to 10 s to allow chemical ionization reactions with the neutral molecules desorbed via LIAD. These initial experiments focused on demonstrating the feasibility of performing LIAD in the LQIT. Hence, the results are compared to those obtained using an FT-ICR mass spectrometer. Despite the lower efficiency in the transfer of desorbed neutral molecules into the ion trap, and the smaller maximum number of available laser pulses, the intrinsically higher sensitivity of the LQIT resulted in a higher sensitivity relative to the FT-ICR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2806935PMC
http://dx.doi.org/10.1021/ac901943kDOI Listing

Publication Analysis

Top Keywords

mass spectrometer
16
ion trap
12
laser-induced acoustic
8
acoustic desorption
8
linear quadrupole
8
quadrupole ion
8
ft-icr mass
8
ft-icr instruments
8
neutral molecules
8
higher sensitivity
8

Similar Publications

To investigate the impact of genetic factors on wine aroma, wines made from 22 clones of five grape varieties ( L.) were used to analyze the volatile compounds by headspace solid phase microextraction gas chromatography mass spectrometer (HS-SPME-GC-MS) and headspace gas chromatography-ion mobility spectrometry (HS-GC-IMS). Results showed that 52 and 49 aroma compounds were identified from 22 clones of wines by two technologies, respectively.

View Article and Find Full Text PDF

Introduction: Recent work identified members of the evolutionarily conserved coronin protein family as key regulators of cell population size. This work originated ~25 years ago through the identification, by two-dimensional gel electrophoresis, of coronin 1 as a host protein involved in the virulence of Mycobacterium tuberculosis. We here describe the journey from a spot on a 2D gel to the recent realization that coronin proteins represent key controllers of eukaryotic cell population sizes, using ever more sophisticated proteomic techniques.

View Article and Find Full Text PDF

Background: Periprosthetic joint infections (PJIs) are a major complication of total joint replacement surgeries. This study investigated the enhancement of mechanical properties and antibiotic release in ultra-high molecular weight polyethylene (UHMWPE) through the encapsulation of submicron gentamicin sulfate (GS) particles, addressing the critical need for improved implant materials in orthopaedic surgery, particularly in managing PJIs.

Methods: The present study involved embedding submicron GS particles into UHMWPE flakes at concentrations of 2% to 10% by weight.

View Article and Find Full Text PDF

Miniaturized mass spectrometers offer significant potential for in situ analysis due to their high specificity and portability. In traditional data-dependent acquisition (DDA) mode, precursor ions for tandem analysis are selected based on the full-scan mass spectrum. However, in situ applications often require the direct analysis of complex samples without extensive sample pretreatment, making them susceptible to chemical noise that can result in false negatives.

View Article and Find Full Text PDF

Development and Validation of a High-Throughput Quantification Method of Crown Procyanidins in Different Wines by UHPLC-Q-TOF.

Methods Protoc

January 2025

Univ. Bordeaux, INRAE, Bordeaux INP, Bordeaux Sciences Agro, UMR 1366, OENO, ISVV, F-33882 Villenave d'Ornon, France.

Procyanidins are widely distributed in plant-derived foods, and consist of flavanol oligomers and polymers. Recently, the crown procyanidin sub-family, characterised by a unique macrocyclic structure, has been identified in grapes and wine. This study reports the development and validation of a rapid and quantitative analytical method measuring crown procyanidin concentration in red and white wines using ultra-high-performance liquid chromatography (UHPLC) coupled with a Q-TOF mass spectrometer.

View Article and Find Full Text PDF