Multiscale image processing and antiscatter grids in digital radiography.

Vet Radiol Ultrasound

Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, 1 Shields Avenue, Davis, CA 95616, USA.

Published: April 2010

Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1740-8261.2009.01585.xDOI Listing

Publication Analysis

Top Keywords

image processing
28
exposure dose
28
digital image
20
dose digital
16
digital radiography
12
image quality
12
digitally processed
12
grid standard
12
standard exposure
12
processing grid
12

Similar Publications

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Monocyte-Derived cxcl12 Guides a Directional Migration of Blood Vessels in Zebra Fish.

Arterioscler Thromb Vasc Biol

January 2025

School of Life Science, Nantong Laboratory of Development and Diseases and Co-Innovation Center of Neuroregeneration, Nantong University, China.

Background: Sprouting blood vessels, reaching the aimed location, and establishing the proper connections are vital for building vascular networks. Such biological processes are subject to precise molecular regulation. So far, the mechanistic insights into understanding how blood vessels grow to the correct position are limited.

View Article and Find Full Text PDF

Background: Dental impressions are crucial in pediatric dentistry, but exaggerated gagging can obstruct this process. Various methods have been proposed to manage the gag reflex (GR).

Aim: This study aimed to evaluate and compare the effectiveness of laser acupuncture and electroacupuncture in controlling children's GR.

View Article and Find Full Text PDF

Time perception in bipolar disorder: a systematic review.

Acta Neuropsychiatr

January 2025

IRCCS Ospedale Policlinico San Martino, Genoa, Italy.

Objective: Time distortions characterise severe mental disorders, exhibiting different clinical and neurobiological manifestations. This systematic review aims to explore the existing literature encompassing experimental studies on time perception in patients with bipolar disorder (BD), considering psychopathological and cognitive correlates.

Methods: Studies using an experimental paradigm to objectively measure the capacity to judge time have been searched for.

View Article and Find Full Text PDF

CardiacField: computational echocardiography for automated heart function estimation using two-dimensional echocardiography probes.

Eur Heart J Digit Health

January 2025

Department of Cardiovascular Surgery of Zhongshan Hospital, Fudan University, Shanghai 200032, China.

Aims: Accurate heart function estimation is vital for detecting and monitoring cardiovascular diseases. While two-dimensional echocardiography (2DE) is widely accessible and used, it requires specialized training, is prone to inter-observer variability, and lacks comprehensive three-dimensional (3D) information. We introduce CardiacField, a computational echocardiography system using a 2DE probe for precise, automated left ventricular (LV) and right ventricular (RV) ejection fraction (EF) estimations, which is especially easy to use for non-cardiovascular healthcare practitioners.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!