Background: Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles.
Objectives: This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis.
Methods: 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis.
Results: Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022).
Conclusions: Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/thx.2009.125146 | DOI Listing |
Acta Chir Orthop Traumatol Cech
January 2025
Department of Orthopedics and Traumatology, Ondokuz Mayıs University, Samsun, Turkey.
Purpose Of The Study: Open (incisional) biopsies have long been accepted as the gold standard in diagnosing bone and soft tissue tumors. However, the main disadvantage of this method is that it can lead to increased contamination, hematoma, infection, and pathological fracture. Compared to open biopsies, percutaneous core needle biopsies are less invasive, do not require hospitalization, have low costs and low complication rates, and there is no need for wound healing in cases that require radiotherapy.
View Article and Find Full Text PDFJ Vet Intern Med
December 2024
Davies Veterinary Specialists, Part of Linnaeus Veterinary Limited, Hitchin, UK.
Background: Approximately 80% of nasal masses in dogs and 91% of nasal masses in cats are reported to be malignant, but the currently reported diagnostic rate of neoplasia is 54% using blind or rhinoscopic biopsy techniques.
Hypothesis/objectives: Describe the technique of computed tomography (CT)-guided Tru-Cut (Tru-Cut biopsy needle, Merit Medical Systems, Utah, USA) nasal biopsies in cats and dogs to determine the diagnostic rate of neoplasia on the first round of sampling and to evaluate the safety of the technique.
Animals: Thirty client-owned animals, 16 dogs and 14 cats, that had CT-guided nasal biopsies performed to investigate nasal masses.
Cureus
October 2024
General Surgery, Calcutta National Medical College and Hospital, Kolkata, IND.
Background Breast cancer is the most frequently diagnosed cancer in women worldwide, accounting for more than one in ten new cancer cases each year. It ranks as the second leading cause of cancer-related mortality among women. The majority of patients present with palpable breast lumps.
View Article and Find Full Text PDFTheriogenology
January 2025
Department of Veterinary Surgery and Animal Reproduction, School of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, SP, Brazil. Electronic address:
This study aimed to evaluate the feasibility of performing multiple testicular biopsies in rams using Tru-cut® needles, assessing histological structure, gene expression, and potential complications such as effects on semen quality, testicular blood flow, and ultrasonographic echotexture. In Exp. 1, six mature rams underwent testicular biopsies at intervals (0, 3, 6, 12, 24, and 48 h) using a 16 G Tru-cut® needle, with alternating testes for each collection.
View Article and Find Full Text PDFClin Transplant
October 2024
Servicio de Cirugía HBP y Trasplante, Hospital Universitari Vall d´Hebron, Vall d´Hebron Institute of Research (VHIR), Barcelona, Spain.
Background: The use of livers with significant steatosis is associated with worse transplantation outcomes. Brain death donor liver acceptance is mostly based on subjective surgeon assessment of liver appearance, since steatotic livers acquire a yellowish tone. The aim of this study was to develop a rapid, robust, accurate, and cost-effective method to assess liver steatosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!