Background: The utility of transcatheter application of radiofrequency energy to eliminate atrioventricular nodal reentrant tachycardia (AVNRT) was investigated.
Methods And Results: Thirty-nine patients (mean age, 53 +/- 20 years; range 14-86 years) with medically refractory AVNRT underwent perinodal ablation with radiofrequency energy. A custom-designed 6F catheter with a large (3-mm-long) distal electrode and interelectrode pacing of 2 mm was used in the majority of cases. The catheter used for ablation was initially positioned across the tricuspid anulus to obtain the largest His bundle electrogram, then withdrawn to obtain the largest atrial:ventricular electrogram ratio, with a small His bundle electrogram (less than or equal to 100 microV). Each application of radiofrequency energy (350-550 kHz, 16.2 +/- 5.2 W) was stopped after 60 seconds or if PR prolongation or an impedance rise was noted. The endpoints of the procedure were persistent modification of atrioventricular nodal conduction (either first-degree atrioventricular block or impairment of ventriculoatrial conduction) and noninducibility of AVNRT before and during isoproterenol administration. Radiofrequency energy was applied a mean of 6.8 +/- 3.5 times per session. After a mean follow-up of 8 +/- 3.0 months, 32 of the 39 patients (82%) have been free of AVNRT, and did not have high grade AV block. Three patients (8%) developed complete atrioventricular block and had pacemakers implanted. Two patients had unsuccessful initial procedures, and two patients had initially successful ablations but had recurrences of tachycardia 4-6 weeks later. Elimination of AVNRT appeared to be due to effects on the retrograde fast pathway in most patients.
Conclusions: Radiofrequency ablation of the perinodal right atrium appears to be safe and effective for treatment of typical AVNRT:
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/01.cir.83.3.827 | DOI Listing |
Med Devices (Auckl)
January 2025
Surgical Research and Development, Surgical Operating Unit, Medtronic, Lafayette, CO, USA.
Purpose: This study compared the performance of the new LigaSure™ XP Maryland Jaw Sealer/Divider (XP Maryland) to that of LigaSure Atlas™ (Atlas) and LigaSure™ Dolphin Tip (Dolphin Tip), two early LigaSure™ (LigaSure) devices characterized by consistent and reliable clinical performance.
Methods: Ex vivo bench testing on porcine renal arteries compared burst pressures, seal times, and rates of sticking, incomplete cuts, and charring between XP Maryland and Atlas and between XP Maryland and Dolphin Tip. In vivo acute testing on a porcine model compared thermal spread, seal times, and rates of hemostasis, sticking, and incomplete cuts between XP Maryland and the two early LigaSure devices.
J Clin Endocrinol Metab
January 2025
Rijnstate, Dept. of Radiology and Nuclear Medicine, Arnhem, The Netherlands.
Context: Radiofrequency ablation (RFA) is used as treatment for symptomatic thyroid nodules. Factors influencing the volume reduction ratio (VRR) at 12 months are not yet fully understood.
Objective: The primary objective was evaluating the VRR at 12 months after RFA.
Nat Mater
January 2025
Condensed Matter Physics and Materials Science Division, Brookhaven National Laboratory, Upton, NY, USA.
Spin waves, or magnons, are essential for next-generation energy-efficient spintronics and magnonics. Yet, visualizing spin-wave dynamics at nanoscale and microwave frequencies remains a formidable challenge due to the lack of spin-sensitive, time-resolved microscopy. Here we report a breakthrough in imaging dipole-exchange spin waves in a ferromagnetic film owing to the development of laser-free ultrafast Lorentz electron microscopy, which is equipped with a microwave-mediated electron pulser for high spatiotemporal resolution.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Biomedical Engineering , University of Wisconsin-Milwaukee College of Engineering and Applied Science, 3203 N Downer Ave, Milwaukee, Milwaukee, Wisconsin, 53211-3029, UNITED STATES.
Capacitive-based radiofrequency (Rf) radiation at 27 MHz offers a non-invasive approach for inducing hyperthermia, making it a promising technique for thermal cancer therapy applications. To achieve focused and site-specific hyperthermia, external material is required that efficiently convert Rf radiation into localized heat. Nanomaterials capable of absorbing Rf energy and convert into heat for targeted ablation are of critical importance.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!