A real-time system for in-home activity monitoring of elders.

Annu Int Conf IEEE Eng Med Biol Soc

Department of Electrical and Computer Engineering, University of Missouri, Columbia, MO, USA.

Published: April 2010

In this paper, we propose a real-time system for in-home activity monitoring and functional assessment for elder care. We describe the development of the whole system which could be used to assist the independent living of elders and improve the efficiency of eldercare practice. With this system, data is collected, silhouettes extracted, features further analyzed and visualized into graphs from which eldercare professionals are able to understand massive video monitoring data within a short period of time. Our experimental results demonstrate that the proposed system is efficient in indoor elder activities monitoring and easily utilized by eldercare professionals.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2009.5334915DOI Listing

Publication Analysis

Top Keywords

real-time system
8
system in-home
8
in-home activity
8
activity monitoring
8
eldercare professionals
8
monitoring
4
monitoring elders
4
elders paper
4
paper propose
4
propose real-time
4

Similar Publications

Computer simulation was utilized to characterize the electrophoretic processes occurring during the enantioselective capillary electrophoresis-mass spectrometry (CE-MS) analysis of ketamine, norketamine, and hydroxynorketamine in a system with partial filling of the capillary with 19 mM (equals 5%) of highly sulfated γ-cyclodextrin (HS-γ-CD) and analyte detection on the cathodic side. Provided that the sample is applied without or with a small amount of the chiral selector, analytes become quickly focused and separated in the thereby formed HS-γ-CD gradient at the cathodic end of the sample compartment. This gradient broadens with time, remains stationary, and gradually reduces its span from the lower side due to diffusion such that analytes with high affinity to the anionic selector become released onto the other side of the focusing gradient where anionic migration and defocusing occur concomitantly.

View Article and Find Full Text PDF

Intelligent two-phase dual authentication framework for Internet of Medical Things.

Sci Rep

January 2025

Department of Computer Science, College of Computer and Information Sciences, King Saud University, Riyadh, 11543, Saudi Arabia.

The Internet of Medical Things (IoMT) has revolutionized healthcare by bringing real-time monitoring and data-driven treatments. Nevertheless, the security of communication between IoMT devices and servers remains a huge problem because of the inherent sensitivity of the health data and susceptibility to cyber threats. Current security solutions, including simple password-based authentication and standard Public Key Infrastructure (PKI) approaches, typically do not achieve an appropriate balance between security and low computational overhead, resulting in the possibility of performance bottlenecks and increased vulnerability to attacks.

View Article and Find Full Text PDF

In this paper, explore the effectiveness of a new Wide Area Fuzzy Power System Stabilizer (WAFPSS), optimized using the Exponential Distribution Optimization (EDO) algorithm, and applied to an IEEE three-area, six-machine power system model. This research primarily focuses on assessing the stabilizer's capability to dampen inter-area oscillations, a critical challenge in power grid operations. Through extensive simulations, the study demonstrates how the WAFPSS enhances stability and reliability under a variety of operational conditions characterized by different communication delay patterns.

View Article and Find Full Text PDF

Background: The cytochrome P450s-mediated metabolic resistance and the target site insensitivity caused by the knockdown resistance (kdr) mutation in the voltage-gated sodium channel (vgsc) gene were the main mechanisms conferring resistance to deltamethrin in Culex quinquefasciatus from Thailand. This study aimed to investigate the expression levels of cytochrome P450 genes and detect mutations of the vgsc gene in deltamethrin-resistant Cx. quinquefasciatus populations in Thailand.

View Article and Find Full Text PDF

Comparison of precision of a paperless electronic input method versus the conventional paper form in an andrology laboratory: a prospective study.

Basic Clin Androl

January 2025

Department of Obstetrics and Gynaecology, School of Clinical Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam Road, Hong Kong SAR, Hong Kong.

Background: Manual counting for semen analysis is recommended by the World Health Organization. Technicians performing this usually record their results on a paper worksheet and then enter the data into an electronic laboratory information system. One disadvantage of this approach is the chance of post-analytical transcription errors, which can be reduced by checking the computer entries before reporting by another technician.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!