A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of pulsatile wall shear stress in compliant arteries: numerical model, validation and experimental data. | LitMetric

Assessment of pulsatile wall shear stress in compliant arteries: numerical model, validation and experimental data.

Annu Int Conf IEEE Eng Med Biol Soc

School of Engineering and Natural and Exact Sciences, Favaloro University, Buenos Aires, Argentina.

Published: March 2010

There is evidence that wall shear stress (WSS) is associated with vascular disease. In particular, it is widely accepted that vascular segments with low or oscillatory values of WSS are more probable to develop vascular disease. It is then necessary to establish a realistic model of the blood flow in blood vessels in order to determine precisely WSS. We proposed a numerical 1D model which takes into account the pulsatile nature of blood flow, the elasticity of the vessel, and its geometry. The model allows the calculation of shear stress. It was validated for stationary situations. Then, we computed the time-dependent WSS distribution from experimental data in the sheep thoracic aorta. Results showed that mean WSS calculated through steady flow and rigid walls models is overestimated. Peak WSS values for pulsatile flow must be considered since they resulted to be at least one order higher than mean values. Oscillations in shear stress in a period showed to be approximately of 40%. These findings show that the proposed model is suitable for estimating time-dependent WSS distributions, and confirm the need of using this kind of model when trying to evaluate realistic WSS in blood vessels.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2009.5333648DOI Listing

Publication Analysis

Top Keywords

shear stress
16
wall shear
8
numerical model
8
experimental data
8
wss
8
vascular disease
8
blood flow
8
blood vessels
8
time-dependent wss
8
model
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!