A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living. | LitMetric

Ambient Assisted Living (AAL) technology is often proposed as a way to tackle the increasing cost of healthcare caused by population aging. However, the sensing technology for continuous respiratory monitoring at home is lacking. Known approaches of respiratory monitoring are based on measuring either respiratory effect, e.g. tracheal sound recording by a bio-acoustic sensor, or respiratory effort, e.g. abdomen movement measurement by a tri-axial accelerometer. This paper proposes a home respiration monitoring system using a tri-axial accelerometer. Three different methods to extract a single respiratory signal from the tri-axial data are proposed and analyzed. The performance of the methods is evaluated for various possible respiration conditions, defined by the sensor orientation and respiration-induced abdomen movement. The method based on Principal Component Analysis (PCA) performs better than selecting the best axis. The analytical approach called Full Angle shows worse results than the best axis when the gravity vector is close to one of the sensor's axes (<15 degrees). Hybrid-PCA, which is a combination of both methods, performs comparable to PCA. The system is evaluated using simulated data from the most common postures, such as lying and sitting, as well as real data collected from five subjects. The results show that the system can successfully reconstruct the respiration-induced movement, which is necessary to determine the respiratory rate accurately.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2009.5333116DOI Listing

Publication Analysis

Top Keywords

respiration monitoring
8
ambient assisted
8
assisted living
8
respiratory monitoring
8
abdomen movement
8
tri-axial accelerometer
8
best axis
8
respiratory
5
performance evaluation
4
tri-axial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!