Objectives: To analyze our experience with laparoscopic partial nephrectomy (LPN) to detail postoperative adverse events and identify factors that may contribute to adverse surgical outcomes. Complications from LPN result from a variety of factors, both technical and inherent.

Methods: Single-center review of 144 consecutive LPN (4 surgeons) performed between November 2002 and January 2008 was conducted. Identified complications were graded using standard reporting criteria. Univariate and multivariate statistical analysis of variables and their association with complication event and blood loss was performed.

Results: A total of 39 complications occurred in 29 (20%) cases. Of these, 20 (51%) were urologic and 19 (49%) were nonurologic. Individual adverse events by grade were as follows: grade I, 6 (15.4%); grade II, 19 (48.7%), grade III, 11 (28.2%), and grade IV, 3 (7.7%). No grade V complications occurred. The median tumor size and ischemia time were 2.7 cm and 35 minutes, respectively. Univariate analysis identified increased American Society of Anesthesiologists risk score (odds ratio 2.99, 95% confidence interval [CI] 1.28, 6.94) and ischemia time (odds ratio 1.31; 95% CI 1.00, 1.71) as associated with complication risk. On multivariate analysis, longer ischemia time was associated with increased estimated blood loss (95% CI 3, 57; P = .03). Hospital readmission and reintervention was required in 15 (10.4%) and 9 (6.2%) patients, respectively.

Conclusions: Complications from LPN occur in a meaningful proportion of procedures although the majority does not require reintervention and half are not urologic. Increasing ischemia time and American Society of Anesthesiologists score are associated with risk for unfavorable surgical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2009.09.036DOI Listing

Publication Analysis

Top Keywords

ischemia time
16
laparoscopic partial
8
partial nephrectomy
8
adverse events
8
surgical outcomes
8
complications lpn
8
blood loss
8
complications occurred
8
american society
8
society anesthesiologists
8

Similar Publications

Introduction: Graft optimization is a necessity in order to develop uterus transplantation from brain-dead donors, as a complement to living donors, as these grafts are rare and the last organs retrieved in multiple organ donation. The aim of this study was to assess the feasibility and interest of hypothermic machine perfusion (HMP) in uterus transplantation using a porcine model; secondary outcomes were the evaluation of the graft's tolerance to a prolonged cold ischaemia time and to find new biomarkers of uterus viability.

Material And Methods: Fifteen uterus allotransplantations were performed in a porcine model, after 18 h of cold ischaemia, divided in three groups: Static cold storage in a HTK solution, HMP (with the VitaSmart (™) machine Bridge to Life Ltd.

View Article and Find Full Text PDF

Pain Perception Threshold in Young High-Altitude Natives After Acute Exposure to Severe Hypoxic Conditions.

Oxygen (Basel)

March 2025

Centro de Investigación en Medicina de Altura (CIMA), Facultad de Medicina Humana, Universidad de San Martín de Porres, Lima 15001, Peru.

Previous studies indicate that individuals at high altitudes have a lower pain threshold than those living at sea level. This study evaluates the differences in pain perception among young people living at an altitude of 3800 m and after acute exposure to a severe hypoxic environment at more than 5100 m. Fourteen people (BMI of 22.

View Article and Find Full Text PDF

Background: Growing evidence indicates that disruptions in mitochondrial quality management contribute to the development of acute kidney injury (AKI), incomplete or maladaptive kidney repair, and chronic kidney disease. However, the temporal dynamics of mitochondrial quality control alterations in relation to renal injury and its recovery remain poorly understood and are addressed in this manuscript.

Method: ology: Male Wistar rats (n = 60) were subjected to varying durations of ischemia and reperfusion.

View Article and Find Full Text PDF

Copy Number Variant Does Not Influence Stroke Severity in 2 C57BL/6J Mouse Models nor in Humans: An Exploratory Study.

Stroke

January 2025

Department of Experimental Neurology, Center for Stroke Research Berlin (CSB), Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Germany (M.F., S.B., S.M., K.W., M.E., A.M., U.D., C.S.).

Background: Contrary to the common belief, the most commonly used laboratory C57BL/6J mouse inbred strain presents a distinctive genetic and phenotypic variability, and for several traits, the genotype-phenotype link remains still unknown. Recently, we characterized the most important stroke survival factor such as brain collateral plasticity in 2 brain ischemia C57BL/6J mouse models (bilateral common carotid artery stenosis and middle cerebral artery occlusion) and observed a Mendelian-like fashion of inheritance of the posterior communicating artery (PcomA) patency. Interestingly, a copy number variant (CNV) spanning locus was reported to segregate in an analogous Mendelian-like pattern in the C57BL/6J colonies of the Jackson Laboratory.

View Article and Find Full Text PDF

Temporal profiling of M-TEER-related complications.

ESC Heart Fail

January 2025

Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University of Düsseldorf, Düsseldorf, Germany.

Aims: Transcatheter edge-to-edge repair of the mitral valve (M-TEER) is known for its low complication rates. However, the optimal level and duration of post-procedural care remain unclear. This study aimed to identify the specific timeframe of post-procedural complications following M-TEER.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!