AI Article Synopsis

  • The study assessed bone formation quality and quantity during maxillary sinus floor elevation using a new synthetic biphasic calcium phosphate (BCP) made of 60% hydroxyapatite and 40% beta-tricalcium phosphate.
  • After a 6-month healing period, the procedure achieved successful bone healing, demonstrated by stable radiological measurements and good osseointegration of dental implants placed subsequently.
  • Histological analysis indicated effective bone formation with new mineralized tissue and low inflammation, providing evidence of the BCP's effectiveness in enhancing bone structure in the upper jaw.

Article Abstract

Objectives: In this study, we evaluated the quality and quantity of bone formation in maxillary sinus floor elevation procedure using a new fully synthetic biphasic calcium phosphate (BCP) consisting of a mixture of 60% hydroxyapatite and 40% of beta-tricalcium phosphate (Straumann Bone Ceramic).

Material And Methods: A unilateral maxillary sinus floor elevation procedure was performed in six patients using 100% BCP. Biopsy retrieval for histological and histomorphometric analysis was carried out before implant placement after a 6-month healing period.

Results: In this study, the maxillary sinus floor elevation procedure with the use of BCP showed uneventful healing. Radiological evaluation after 6 months showed maintenance of vertical height gained immediately after surgery. Primary stability was achieved with all Straumann SLA dental implants of 4.1 mm diameter and 10 or 12 mm length. The implants appeared to be osseointegrated well after a 3-month healing period. Histological investigation showed no signs of inflammation. Cranial from the native alveolar bone, newly formed mineralized tissue was observed. Also, osteoid islands as well as connective tissue were seen around the BCP particles, cranial from the front of newly formed mineralized tissue. Close bone-to-substitute contact was observed. Histomorphometric analysis showed an average bone volume/total volume (BV/TV) of 27.3% [standard deviation (SD) 4.9], bone surface/total volume (BS/TV) 4.5 mm(2)/mm(3) (SD 1.1), trabecula-thickness (TbTh) 132.1 mum (SD 38.4), osteoid-volume/bone volume (OV/BV) 7.5% (SD 4.3), osteoid surface/bone surface (OS/BS) 41.3% (SD 28.5), osteoid thickness (O.Th) 13.3 mum (SD 4.7) and number of osteoclasts/total area (N.Oc/Tar) 4.4 1/mm (SD 5.7).

Conclusions: Although a small number of patients were treated, this study provides radiological and histological evidence in humans confirming the suitability of this new BCP for vertical augmentation of the atrophied maxilla by means of a maxillary sinus floor elevation procedure allowing subsequent dental implant placement after a 6-month healing period. The newly formed bone had a trabecular structure and was in intimate contact with the substitute material, outlining the osteoconductive properties of the BCP material. Bone maturation was evident by the presence of lamellar bone.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2009.01821.xDOI Listing

Publication Analysis

Top Keywords

maxillary sinus
20
sinus floor
20
floor elevation
20
elevation procedure
20
6-month healing
12
healing period
12
newly formed
12
straumann bone
8
radiological histological
8
histological histomorphometric
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!