Surface characterization of commercial oral implants on the nanometer level.

J Biomed Mater Res B Appl Biomater

Department of Biomaterials/Handicap Research, Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden.

Published: February 2010

Lately, there has been a growing interest in how the presence of nanometer structures on a bone integrated implant surface influences the healing process. Recent in vitro studies have revealed an increased osteoblast response to different nanophase surfaces. Some commercial implant brands claim their implants have nanometer structures. However, at present, there are no studies where the nano topography of today's commercially available oral implants has been investigated. The aim of this study was to characterize commercial oral implants on the nanometer level and to investigate whether or not the nanometer surface roughness was correlated to the more well-known micrometer roughness on the implants. Twelve different commercial screw-shaped oral implants with various surface modifications were examined using scanning electron microscopy and a white light interferometer. The interferometer is suitable for detection of nanoscale roughness in the vertical dimension; however, limitation exists on the horizontal due to the wavelength of the light. A 1 x 1 microm Gaussian filter was found to be useful for identifying nm roughness with respect to height deviation. The results demonstrated that an implant that was smooth on the micrometer level was not necessarily smooth on the nanometer level. Different structures in the nanometer scale was found on some of the implants, indicating that to fully understand the relationship between the properties of an implant surface and its osseointegration behavior, a characterization at the nanometer scale might be relevant.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.31538DOI Listing

Publication Analysis

Top Keywords

oral implants
16
implants nanometer
12
nanometer level
12
commercial oral
8
nanometer
8
nanometer structures
8
implant surface
8
nanometer scale
8
implants
7
surface
5

Similar Publications

Background: This study aimed to investigate the quality and readability of online English health information about dental sensitivity and how patients evaluate and utilize these web-based information.

Methods: The credibility and readability of health information was obtained from three search engines. We conducted searches in "incognito" mode to reduce the possibility of biases.

View Article and Find Full Text PDF

Purpose: The study assessed the clinical outcomes following treatment of peri-implant mucositis using Er:YAG laser or an ultrasonic device over six months. Patients' experience of pain, aesthetics, and Quality of life were further assessed.

Methods: One dental implant, per included patient, diagnosed with peri-implant mucositis underwent treatment with an Er:YAG laser (test) or an ultrasonic scaler (control) randomly.

View Article and Find Full Text PDF

Implants aim to restore skeletal dysfunction associated with ageing and trauma, yet infection and ineffective immune responses can lead to failure. This project characterized the microbiological and host cell responses to titanium alloy with or without electroplated metallic copper. Bacterial viability counting and scanning electron microscopy quantified and visualized the direct and indirect bactericidal effects of the Cu-electroplated titanium (Cu-Ep-Ti) against two different Staphylococcus aureus strains.

View Article and Find Full Text PDF

Objectives: The primary objective of this systematic review was to analyze the overall prevalence of distal caries in mandibular second molars (MSMs) associated with the presence of impacted mandibular third molars (IMTMs). Secondary objectives were to determine how IMTM position and level of impaction influence the occurrence of distal caries.

Materials And Methods: PRISMA guidelines were followed.

View Article and Find Full Text PDF

Purpose: Preoperative virtual planning and osteosynthesis with patient-specific implants (PSIs) have become a quotidian approach to many maxillofacial elective surgery setups. When a process is well-organized, a similar approach can be harnessed to serve the needs of exact primary reconstructions, especially in midfacial trauma cases. PSI osteosynthesis of the mandible is, however, more challenging because a mirror technique of the facial sides is often unreliable due to inherent lack of symmetry, and movement of the mandible increases the risk of loosening of the osteosynthesis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!