Nitinol alloys are rapidly being utilized as the material of choice in a variety of applications in the medical industry. It has been used for self-expanding stents, graft support systems, and various other devices for minimally invasive interventional and endoscopic procedures. However, the biocompatibility of this alloy remains a concern to many practitioners in the industry due to nickel sensitivity experienced by many patients. In recent times, several new Nitinol alloys have been introduced with the addition of a ternary element. Nevertheless, there is still a dearth of information concerning the biocompatibility and corrosion resistance of these alloys. This study compared the biocompatibility of two ternary Nitinol alloys prepared by powder metallurgy (PM) and arc melting (AM) and critically assessed the influence of the ternary element. ASTM F 2129-08 cyclic polarization in vitro corrosion tests were conducted to evaluate the corrosion resistance in phosphate buffered saline (PBS). The growth of endothelial cells on NiTi was examined using optical microscopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2760990 | PMC |
http://dx.doi.org/10.1007/s11665-009-9435-5 | DOI Listing |
PLoS One
December 2024
Bio-Inspired Technology Group, Faculty of Mechanical Engineering, Department of BioMechanical Engineering, Delft University of Technology, Delft, The Netherlands.
Pedicle screws have long been established as the gold standard for spinal bone fixation. However, their fixation strength can be compromised in cases of low bone density, particularly in osteoporotic bone, due to the reliance on a micro-shape lock between the screw thread and the surrounding bone. To address this challenge, we propose augmenting conventional pedicles screws with a curved compliant anchor.
View Article and Find Full Text PDFHeliyon
May 2024
Department of Solid Mechanics, Faculty of Mechanical Engineering, University of Kashan, Kashan, P.O. Box 87317-53153, Iran.
J Foot Ankle Surg
December 2024
Orthopedic Foot and Ankle Center, 350 W. Wilson Bridge Rd, Ste. 200, Worthington, OH 43085. Electronic address:
Many fixation options exist for correction of a hallux valgus (HV) deformity with a first tarsometatarsal (TMT) joint arthrodesis with pros and cons to each. Few have looked at utilizing a SMA (shape memory alloy) staple made from nitinol for fixation. This study evaluates the effectiveness of a modified Lapidus technique using a nitinol (shape memory alloy) staple combined with a two-screw construct for first tarsometatarsal (TMT) joint arthrodesis in correcting hallux valgus (HV) deformity.
View Article and Find Full Text PDFIndian J Orthop
December 2024
University Hospital Coventry and Warwickshire NHS Trust, Clifford Bridge Rd, Coventry, CV2 2DX UK.
Background: Continuous compression implants (CCIs) can provide continuous compression across a fracture site. They are mainly used in foot/ankle surgery, with very limited descriptions in the literature of their potential for trauma. The aim of this study was to describe the use and associated outcomes of CCIs in modern day trauma practice.
View Article and Find Full Text PDFBiomed Eng Online
November 2024
Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119, Rostock, Germany.
Background: Chronic venous insufficiency (CVI) is a common disease with a high prevalence. Incompetent venous valves are considered as one of the main causes. Besides compression therapy, various surgical therapies are practiced, whereby the reconstruction of valves is of central importance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!