Use of a new exsanguination tourniquet in internal fixation of distal radius fractures.

Tech Hand Up Extrem Surg

Department of Orthopedic and Traumatology B', Rambam Medical Center, Haifa, Israel.

Published: December 2009

We describe our experience using a new device that results in a bloodless field in open repair of distal radius fractures. The device, an exsanguinating tourniquet (HemaClear model/40, OHK Medical Devices, Haifa, Israel), replaces the traditional methods of limb elevation, Esmarch bandaging, pneumatic tourniquet pressurizing and the associated components. HemaClear/40 is an elastic silicon ring with a tubular elastic sleeve rolled onto it. The device has attached straps that, when pulled, unroll the sleeve, rolling the ring mesially on the limb. The pressure exerted by rolling HemaClear/40 is supra-systolic thereby exsanguinating the limb and occluding the arterial inflow. Our experience in 49 patients demonstrated quick application, superior exsanguination and that the device could be placed on the forearm instead of the upper arm. No side effects or complications were noted. In our opinion, the fact that HemaClear/40 is a sterile, single-patient device makes it superior over the traditional technology.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BTH.0b013e3181b56187DOI Listing

Publication Analysis

Top Keywords

distal radius
8
radius fractures
8
device
5
exsanguination tourniquet
4
tourniquet internal
4
internal fixation
4
fixation distal
4
fractures describe
4
describe experience
4
experience device
4

Similar Publications

HIV-related mortality has fallen due to scale-up of antiretroviral therapy (ART), so more women living with HIV (WLH) now live to reach menopause. Menopausal estrogen loss causes bone loss, as do HIV and certain ART regimens. However, quantitative bone data from WLH are few in Africa.

View Article and Find Full Text PDF

Background: Radial bowing is necessary for forearm rotation. Fractures or deformities of the forearm that affect the radial bow may disrupt normal forearm rotation.

Objective: The purpose of this study was to evaluate the development and establish normative values for the pediatric and adolescent radial bow.

View Article and Find Full Text PDF

Nonlinear homogenised finite element (hFE) models can accurately predict stiffness and strength of ultra-distal sections of the radius and tibia using in vivo HR-pQCT images. Recent findings showed good stiffness prediction at these distal sections but a limited ability to reproduce experimental strain localisation. The coarseness of voxel-based meshes reduces the computational effort at the cost of heavily simplifying the underlying geometry of the cortex, the gradient of material properties, and the resulting strain distribution.

View Article and Find Full Text PDF

Objective: Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.

Methods: Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old.

View Article and Find Full Text PDF

Objective: Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.

Methods: PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!