Study Design: Comparison of the biomechanical fixation strengths offered by 3 iliac screw fixation techniques: short screw, short screw augmented with cement, and long screw.

Objective: Evaluate the effect of screw length and bone cement augmentation on the fixation strength of iliac screw upon fatigue loading.

Summary Of Background Data: Iliac screws have been used in treating spinal disorders such as spinal deformity, spondylolisthesis, and sacral tumor. In clinical practices, both short screws and long screws are being used. It has been reported that short iliac screws have a higher rate of loosening. Therefore, short iliac screws are being used with bone cement augmentation to improve fixation. To date, no biomechanical study has compared the strengths of these 3 different iliac screw fixation techniques.

Method: Fresh, frozen human cadaveric pelvis specimens (n = 18, 12 males, 6 females, average age 61 y) were used. Bone density was measured to characterize bone quality. The specimens were randomly divided into 2 groups. In group 1 (n = 8), short screws of 7.0-mm diameter and 70 + or - 4 mm length (as the length of exceeding over ischial notch) and long screw of 7.0-mm diameter and 120 + or - 4 mm length were placed on either side of the pelvis (left and right). In group 2 (n = 10), short iliac screws were placed after augmentation with polymethyl methacrylate bone cement on 1 side of the pelvis and long iliac screw were placed on the other side (left and right). Cyclic loading ranging from 20 to 200 N was applied to each screw at a frequency of 2 Hz up to 5000 cycles. Pullout tests were then conducted at the rate of 5 mm/min after the fatigue test, and the maximum pullout strength for each screw was recorded and analyzed.

Results: The maximum pullout strength of the long screw and short screw groups after fatigue conditioning were 2386 + or - 1470 and 833 + or - 681 N respectively. Significant difference was found between the 2 groups (P < 0.05). The short iliac screw had a higher loosening rate. The pullout force of the short screw fixation with augmentation and the long screw fixation after cyclic loading were 2436 + or - 915 and 2529 + or - 1055 N, respectively. No significant difference was found between the 2 groups (P > 0.05).

Conclusions: Short iliac screws are susceptible to loosening after cyclic loading. Bone cement augmentation of short screws has demonstrated a significant increase in the fixation strength of short screws to an extent similar to that of long iliac screws. Thus, short iliac screw fixation after augmentation with bone cement will be a viable clinical option for spino-pelvic reconstruction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0b013e3181929e0cDOI Listing

Publication Analysis

Top Keywords

iliac screws
28
bone cement
24
iliac screw
24
short iliac
24
screw fixation
20
screw
17
cement augmentation
16
short screw
16
short screws
16
short
14

Similar Publications

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

Background: There is no consensus in the literature regarding the optimal treatment method for posterior pelvic ring injuries. This study aims to compare the radiologic and clinical outcomes, as well as complications of spinopelvic fixation (SPF) and iliosacral screw fixation (ISF) in patients with posterior pelvic ring injuries.

Methods: This retrospective study analyzed 54 patients (37 females, 17 males; mean age 38.

View Article and Find Full Text PDF

Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of two types of bone grafts (packed cancellous vs. corticocancellous) used in repairing scaphoid waist nonunion fractures with volar locking plates.
  • Postoperative CT scans showed that 95% of patients achieved osseous bridging, but those with packed cancellous grafts had significantly better healing outcomes than those with corticocancellous grafts.
  • The findings suggest that using packed cancellous autografts may lead to faster and more effective bone healing in these cases.
View Article and Find Full Text PDF

Objective: There are many advantages to stabilize the posterior pelvic ring injuries with a transiliac-transsacral (TITS) screw percutaneously. To identify the correct entry point and insert a guidewire accurately for a TITS screw, we propose a method of specifying the optimal entry point, and introduce a technique of enabling freehand placement of a guidewire with fluoroscopic guidance.

Methods: In this retrospective study, 116 patients who underwent pelvic CT scans and pelvic lateral radiographs at our institution from January 2020 to April 2022 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!