A problem of higher background value and lower measured Cd value exists when Cd is digested by conventional dry digestion method, measured by graphite furnace atomic absorption, and calculated with peak height numeration. This problem results in difficulty for evaluating samples with Cd contents in the neighborhood of critical values. In order to solve the problem, the present paper focused on background measurement with graphite furnace atomic absorption, modified the pre-preparation procedures of the traditional method, and screened the optimal concentration of the modifier. Results showed that addition of Mg (NO3)2 as a modifier into the samples before incineration was preferred. It could not only yield a clear solution but also reduce its background by ten times, considerably eliminating background interference. In addition, using 3% HNO3 in stead of 1 mol x L(-1) HCl as dilution for the incinerated sample could eliminate the background. The improved methods could acquire a zero concentration of measurement for the blank, re-correct the values measured by graphite furnace atomic absorption and obtain more reliable results.

Download full-text PDF

Source

Publication Analysis

Top Keywords

graphite furnace
16
furnace atomic
12
atomic absorption
12
measurement graphite
8
measured graphite
8
background
6
[methodology improvement
4
improvement background
4
background elimination
4
elimination plant
4

Similar Publications

A three-dimensional numerical model of the vacuum sintering furnace was established, combined with the custom program of temperature-voltage feedback regulation. Through simulationand experimental validation, the heating and holding stage as well as the thermal hysteresis phenomenon of the furnace were analyzed, a dimensionless quantity of hysteresis temperature difference was proposed and calculated, the distribution of the electric field and temperature uniformity of the furnace were discussed in detail, while the structural improvement approach was proposed based on simulation. The results show that: during the heating process, the maximum of thermal hysteresis temperature difference between the graphite cylinder and the heating tube is 0.

View Article and Find Full Text PDF

Heavy metal pollution, particularly from cadmium (Cd) and copper (Cu), poses significant environmental and health risks. To address the need for efficient, portable, and sensitive detection methods, this study introduces an improved atmospheric pressure glow discharge atomic emission spectrometry (APGD-AES) technique for quantifying Cd and Cu in water samples. The APGD-AES method offers key advantages, including low energy consumption (<33 W), high excitation energy, and compact design.

View Article and Find Full Text PDF

Surface water from springs, rivers, and dams is often used as an unconventional drinking water source in rural areas where potable water is often unavailable. However, this practice carries significant health risks due to potential contaminants. In this study, the concentrations of arsenic (As) and chromium (Cr) were assessed seasonally using graphite furnace atomic absorption spectrometry (GFAAS).

View Article and Find Full Text PDF

Development of a fully automated slurry sampling introduction system for GF-AAS and its application for the determination of cadmium in different matrices.

Anal Chim Acta

January 2025

Federal Institute for Materials Research and Testing, Division 1.1 - Inorganic Trace Analysis, Richard-Willstätter-Straße 11, 12489, Berlin, Germany; Federal Institute for Materials Research and Testing, Division 1.4 - Process Analytical Technology, Richard-Willstätter-Straße 11, 12489, Berlin, Germany. Electronic address:

Article Synopsis
  • Graphite Furnace-Atomic Absorption Spectrometry (GF-AAS) is highly sensitive for trace element analysis but struggles with solid sample preparation, like soils and microplastics, due to time-consuming methods that increase measurement uncertainty and carbon footprints.
  • A novel autosampler extension has been developed to enhance GF-AAS by ensuring sample suspension stability and preventing evaporation and contamination, offering reliable results with impressive recovery rates in various materials.
  • This advancement streamlines trace element analysis in complex samples, making it an essential tool for environmental monitoring and regulatory compliance while improving accuracy and efficiency in high-throughput settings.
View Article and Find Full Text PDF

A phenylarsenic compounds, which contain arsenic (As), are chemical warfare agents; therefore, they are detected only in specific areas. Phenylarsenic compounds have gained significant research interest owing to their historical background, toxicology, and potential risks to human metabolism. However, research progress in this field has been limited because of the lack of standard materials, which ensure the chemical species and its concentration, required for analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!