The success of cardiac resynchronization therapy (CRT) depends on a high percentage of ventricular pacing. We present the electrocardiography and electrograms of a patient who underwent an implantable cardioverter-defibrillator (ICD) with CRT implantation showing a low percentage of ventricular pacing as a result of T wave oversensing of paced QRS. The patient showed no clinical improvement. We suggest finding a good sensitivity of F waves in induced ventricular fibrillation during ICD implantation in order to overcome the harm of possible oversensing.

Download full-text PDF

Source

Publication Analysis

Top Keywords

wave oversensing
8
low percentage
8
cardiac resynchronization
8
resynchronization therapy
8
percentage ventricular
8
ventricular pacing
8
oversensing low
4
percentage biventricular
4
biventricular pacing
4
pacing cardiac
4

Similar Publications

Introduction: The novel Confirm Rx™ implantable cardiac monitor (ICM) with SharpSense™ technology incorporates a new P-wave discriminator designed to improve AF detection. This study aimed to evaluate the diagnostic performance of the Confirm Rx™ ICM in detecting AF episodes of varying durations.

Methods: We conducted a multicenter retrospective analysis of consecutive patients implanted with a Confirm Rx™ ICM (v1.

View Article and Find Full Text PDF
Article Synopsis
  • Patients with subcutaneous implantable cardioverter-defibrillators (S-ICDs) experience oversensing episodes (OS) more frequently than those with traditional transvenous ICDs, indicating a need for better detection methods.
  • A study of 21 patients found that 28.6% experienced OS, particularly among those with Brugada/J wave syndrome, and determined that a significantly lower QRS amplitude in the synthesized V7 lead (synV7) was linked to OS incidence.
  • The study suggests that a synV7 QRS amplitude of less than 0.61 mV can effectively predict the occurrence of OS, highlighting the need for monitoring this parameter in patients with S-ICDs.
View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the long-term performance and safety of the extravascular implantable cardioverter-defibrillator (EV ICD) after initial findings showed its effectiveness for 6 months.
  • A total of 316 patients were enrolled, with a successful implant in 299 cases, experiencing various arrhythmic events that were effectively treated using antitachycardia pacing (ATP) and shocks.
  • The results indicated high success rates for both ATP (77.1%) and shock therapy (100%), with low rates of complications and inappropriate shocks over the three-year study period.
View Article and Find Full Text PDF
Article Synopsis
  • Left bundle branch area pacing (LBBAP) shows promise as a safe and effective alternative for cardiac resynchronization therapy (CRT) in patients with implantable cardioverter-defibrillators (ICD).
  • A study assessed the feasibility and safety of a traditional defibrillator lead in the LBBAP location, finding a 62.5% acute procedural success rate with some patients needing lead repositioning.
  • Follow-up results for an average of 3.8 months indicated stable pacing parameters with no inappropriate arrhythmia detection or therapy issues, supporting LBBAP as a viable option.*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!