A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is the soft-start polymerisation concept still relevant for modern curing units? | LitMetric

Is the soft-start polymerisation concept still relevant for modern curing units?

Clin Oral Investig

Department of Restorative Dentistry, Dental School of the Ludwig-Maximilians-University, Goethestr. 70, 80336 Munich, Germany.

Published: February 2011

Shrinkage stress, degree of cure and mechanical properties are contradicting properties, forcing to a compromise between an adequate curing and low stress at the interface tooth-restoration. The purpose of this study was to quantify this relations for a micro-hybrid composite, by analysing in real time the development of degree of cure at depths of 2 and 6 mm, shrinkage stress and curing time until gelation, as well as the variation of micro-mechanical properties with depth, after curing with 13 regimes of one halogen and two light-emitting diode (LED) curing units. A nano-dynamic mechanical test was additionally performed on selected regimes (Ramp, Pulse and Fast Cure) of the same curing unit. The present study showed that the soft-start polymerization concept is still valid for less deep cavities (2 mm), even by curing with high-power LED curing units, since a soft-cure polymerization resulted in a delayed gel point and a lower shrinkage stress, keeping simultaneously the degree of cure and mechanical properties constant. At 6 mm depth, curing with soft-start regimes resulted in a significant decrease in degree of cure, although this decrease was less than 10%, while the mechanical properties were maintained.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-009-0354-5DOI Listing

Publication Analysis

Top Keywords

degree cure
16
shrinkage stress
12
mechanical properties
12
curing
9
cure mechanical
8
depth curing
8
led curing
8
curing units
8
cure
5
properties
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!