A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MRI after implantation of a novel femoral closure device following intra-arterial catheterisation: implications for subsequent contrast-enhanced MR angiography. | LitMetric

Objective: To assess MRI safety aspects and artefacts of a novel femoral artery closure device during contrast-enhanced MR angiography in patients following intra-arterial catheterisation.

Methods: Ten consecutive patients underwent MRI within 24 h of coronary angiography and placement of a femoral artery closure device. We used a T2-weighted gradient-echo MRI sequence to measure the device-related artefact size in comparison with a phantom image, phase-contrast flow measurement proximal to, at the level of and distal to the device to quantify potential differences in flow velocity and contrast-enhanced 3D gradient-echo MR angiography to differentiate potential femoral artery stenosis from device-related artefacts.

Results: The mean size of the oval-shaped artefact was 8.4 x 6.6 mm (+/-1.0 x 0.8 mm) and was almost identical to the maximum artefact size of the phantom measurement (8.3 x 5.7 mm). Device placement did not result in an increased peak velocity (proximal 69 +/- 23 cm/s, at the level of 64 +/- 11 cm/s and distal to the device 63 +/- 12 cm/s, p = 0.67). The mean artefact penetration into the vessel lumen was 0.5 +/- 0.5 mm (percentage vessel narrowing 7.0 +/- 6%; range 0-16%).

Conclusion: The MR conditional StarClose femoral artery closure device was used safely within 24 h of deployment at 1.5 T. Despite clip-related artefacts MR angiography will allow for easy differentiation of clip-related artefacts from high-grade atherosclerotic stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-009-1661-6DOI Listing

Publication Analysis

Top Keywords

closure device
16
femoral artery
16
artery closure
12
+/- cm/s
12
novel femoral
8
contrast-enhanced angiography
8
artefact size
8
distal device
8
clip-related artefacts
8
device
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!