Real-time fault detection and isolation in biological wastewater treatment plants.

Water Sci Technol

Department of Systems and Computers, University of Florence, Via S. Marta, 3-50139, Florence, Italy.

Published: April 2010

Automatic fault detection is becoming increasingly important in wastewater treatment plant operation, given the stringent treatment standards and the need to protect the investment costs from the potential damage of an unchecked fault propagating through the plant. This paper describes the development of a real-time Fault Detection and Isolation (FDI) system based on an adaptive Principal Component Analysis (PCA) algorithm, used to compare the current plant operation with a correct performance model based on a reference data set and the output of three ion-specific sensors (Hach-Lange gmbh, Düsseldorf, Germany): two Nitratax NOx UV sensors, in the denitrification tank and downstream of the oxidation tanks, where an Amtax ammonium-N sensor was also installed. The algorithm was initially developed in the Matlab environment and then ported into the LabView 8.20 (National Instruments, Austin, TX, USA) platform for real-time operation using a compact Field Point, a Programmable Automation Controller by National Instruments. The FDI was tested with a large set of operational data with 1 min sampling time from August 2007 through May 2008 from a full-scale plant. After describing the real-time version of the PCA algorithm, this was tested with nine months of operational data which were sequentially processes by the algorithm in order to simulate an on-line operation. The FDI performance was assessed by organizing the sequential data in two differing moving windows: a short-horizon window to test the response to single malfunctions and a longer time-horizon to simulate multiple unrepaired failures. In both cases the algorithm performance was very satisfactory, with a 100% failure detection in the short window case, which decreased to 84% in the long window setting. The short-window performance was very effective in isolating sensor failures and short duration disturbances such as spikes, whereas the long term horizon provided accurate detection of long-term drifts and proved robust enough to allow for some delay in failure recovery. The system robustness is based on the use of multiple statistics which proved instrumental in discriminating among the various causes of malfunctioning.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2009.723DOI Listing

Publication Analysis

Top Keywords

fault detection
12
real-time fault
8
detection isolation
8
wastewater treatment
8
plant operation
8
pca algorithm
8
national instruments
8
operational data
8
detection
5
algorithm
5

Similar Publications

The application of 2D materials for detecting dissolved gas molecules is essential for identifying faults in oil-immersed transformers. This study investigates the adsorption properties of ZrCl monolayer (ML) and Pd-doped ZrCl ML with six gas molecules (CO, CO, CH, CH, CH, CH) in transformer oil using the density functional approach. The adsorption behaviour was analysed by calculating and comparing the structures, charge transfer and adsorption energies.

View Article and Find Full Text PDF

Belt conveyor idler fault detection algorithm based on improved YOLOv5.

Sci Rep

January 2025

School of Intelligent Manufacturing and Modern Industry (School of Mechanical Engineering), Xinjiang University, Ürümqi, 830017, China.

The rapid expansion of the coal mining industry has introduced significant safety risks, particularly within the harsh environments of open-pit coal mines. The safe and stable operation of belt conveyor idlers is crucial not only for ensuring efficient coal production but also for safeguarding the lives of coal mine workers. Therefore, this paper proposes a method based on deep learning for real-time detection of conveyor idler faults.

View Article and Find Full Text PDF

This paper presents an open-source dataset intended to enhance the analysis and optimization of photovoltaic (PV) power generation in urban environments, serving as a valuable resource for various applications in solar energy research and development. The dataset comprises measured PV power generation data and corresponding on-site weather data gathered from 60 grid-connected rooftop PV stations in Hong Kong over a three-year period (2021-2023). The PV power generation data was collected at 5-minute intervals at the inverter-level.

View Article and Find Full Text PDF

A novel swarm budorcas taxicolor optimization-based multi-support vector method for transformer fault diagnosis.

Neural Netw

January 2025

School of Automation Science and Engineering, South China University of Technology, Guangzhou, 510640, China; Key Laboratory of Autonomous Systems and Network Control, Ministry of Education, South China University of Technology, Guangzhou, 510640, China; Institute for Super Robotics (Huangpu), Guangzhou, 510555, China; Nanchang University, Nanchang, 330031, China; College of Computer Science and Engineering, Jishou University, Jishou, 416000, China; Guangdong Artificial Intelligence and Digital Economy Laboratory (Pazhou Lab), Guangzhou, 510335, China; School of Electronical Engineering, Shaanxi University of Technology, Hanzhong, 723001, China; School of Information Science and Engineering, Changsha Normal University, Changsha, 410100, China; Institute of Artificial Intelligence and Automation, Guangdong University of Petrochemical Technology, Maoming, 525000, China. Electronic address:

To address the challenge of low recognition accuracy in transformer fault detection, a novel method called swarm budorcas taxicolor optimization-based multi-support vector (SBTO-MSV) is proposed. Firstly, a multi-support vector (MSV) model is proposed to realize multi-classification of transformer faults based on dissolved gas data. Then, a swarm budorcas taxicolor optimization (SBTO) algorithm is proposed to iteratively search the optimal model parameters during MSV model training, so as to obtain the most effective transformer fault diagnosis model.

View Article and Find Full Text PDF

Data-driven fault detection and diagnosis methods in wastewater treatment systems: A comprehensive review.

Environ Res

January 2025

Jiangsu Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, Nanjing Forestry University, Nanjing, 210037, China; Shandong Huatai Paper Co. Ltd., Dongying, 257335, China. Electronic address:

Wastewater treatment systems are essential for sustainable water resource management but face challenges such as equipment and sensor malfunctions, fluctuating influent conditions, and operational disturbances that compromise process stability and detection accuracy. To address these challenges, this paper systematically reviews data-driven fault detection and diagnosis (FDD) methods applied in wastewater treatment systems from 2014 to 2024, focusing on their applications, advancements, and limitations. Main contributions include an overview of key treatment processes, a detailed evaluation of fault types (process and sensor faults), advancements in multivariate statistical methods, machine learning (ML), and hybrid FDD techniques, as well as their effectiveness in anomaly detection, managing complex data distributions, and enabling real-time monitoring.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?