A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Phosphate removal from source separated urine by electrocoagulation using iron plate electrodes. | LitMetric

Phosphate removal from source separated urine by electrocoagulation using iron plate electrodes.

Water Sci Technol

School of Life and Environmental Science, Wenzhou University, No 276, Xue-Yuan Road, Lu-cheng District, Wenzhou 325027, China.

Published: April 2010

The aim of this study was to investigate the effects of current density, gap between electrodes, urine dosage, dilution and hydrolysis on phosphate removal from human urine by electrocoagulation technique using iron as electrodes. It was shown that, although a high current density and a long electrolysis time favored the removal of phosphate, an appropriate value for these two parameters can be obtained by taking into account the consumption of energy and iron in addition to P removal. In this study, current density 40 mA/cm2 and electrolysis time 20 min were shown to be optimal for 1.0 L pure urine to achieve nearly a complete removal (98%) efficiency of phosphate under the conditions of electrode area 160 cm2, the stirring speed 150 rpm, and the gap between electrodes 5 mm. Increase of gap between electrodes had little effect on phosphate removal, although it increased the energy consumption dramatically. The use of a high urine dosage reduced the efficiency of phosphate removal but increased the amount of removed phosphate. When pure urine was diluted with tap water, use of a higher tap water proportion for dilution expedited the electrolysis to achieve a nearly complete removal of phosphate in solution, but dilution caused the increase in energy consumption. It was also revealed that the hydrolysis of urine prior to electrocoagulation treatment impeded phosphate removal.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2009.309DOI Listing

Publication Analysis

Top Keywords

phosphate removal
20
current density
12
gap electrodes
12
phosphate
9
urine electrocoagulation
8
urine dosage
8
removal
8
electrolysis time
8
removal phosphate
8
pure urine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!