A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device. | LitMetric

Background: The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail.

Methods And Results: We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMate II continuous-flow left ventricular assist device for bridge to transplantation. To determine whether patients with impaired renal and hepatic function improve over time with continuous-flow left ventricular assist device support or whether there are any detrimental effects in patients with normal organ function, we divided patients into those with above-normal and normal laboratory values before implantation and measured blood chemistry over time during left ventricular assist device support. There were significant improvements over 6 months in all parameters in the above-normal groups, with values in the normal groups remaining in the normal range over time. Mean blood urea nitrogen and serum creatinine in the above-normal groups decreased significantly from 37+/-14 to 23+/-10 mg/dL (P<0.0001) and from 1.8+/-0.4 to 1.4+/-0.8 mg/dL (P<0.01), respectively. There were decreases in aspartate transaminase and alanine transaminase in the above-normal groups from 121+/-206 and 171+/-348 to 36+/-19 and 31+/-22 IU (P<0.001), respectively. Total bilirubin for the above-normal group was 2.1+/-0.9 mg/dL at baseline; after an acute increase at week 1, it decreased to 0.9+/-0.5 mg/dL by 6 months (P<0.0001). Both renal and liver values from patients in the normal groups remained normal during support with the left ventricular assist device.

Conclusions: The HeartMate II continuous-flow left ventricular assist device improves renal and hepatic function in advanced heart failure patients who are being bridged to transplantation, without evidence of detrimental effects from reduced pulsatility over a 6-month time period.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.108.814863DOI Listing

Publication Analysis

Top Keywords

left ventricular
16
ventricular assist
16
assist device
16
renal hepatic
8
hepatic function
8
function improve
8
advanced heart
8
heart failure
8
failure patients
8
organ function
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!