Heterogeneous lung and bone phantoms have been constructed for the purpose of testing monitor unit calculations at or near interfaces for different planning systems. Data have been acquired for 2 linear accelerators: a Varian 2300cd (6 and 25 MV) and an Elekta Synergy (6, 10, and 18 MV). We have reviewed Pinnacle and the correction-based, pre-AAA version of Eclipse planning systems with the intent of exploring the limits of these systems with energy and field size. Data were acquired from 2 x 2 to 10 x 10 cm(2) field sizes over the available range of energies. Our measurements confirm that Pinnacle predicts doses mostly to within +/- 5%, even near lung-tissue interfaces over the full range of energies and field sizes tested. The Eclipse-modified Batho and equivalent TMR algorithms overpredicted doses by 10% or more in the lung and near the lung-tissue interfaces if the field size was less than 10 x 10 cm(2) when the energy was 18 MV or higher. At lower energies, the field size had to be at least 6 x 6 cm(2) for calculated doses to be within 10% of measurement. For bone-tissue interfaces, doses were generally underestimated by 5% to 10% or more by all calculation methods over the range of field sizes and energies reviewed. A second goal of this study was to review methods for hand-checking monitor units when heterogeneities are included. We evaluated the range of applicability of 2, one-dimensional (1D) inhomogeneity correction factors: the effective attenuation method and the TMR ratio method. The effective attenuation method for monitor unit checking was within +/- 5% to as small as 6 x 6 cm(2) fields for 6 to 10 MV, usable for 4 x 4 cm(2) fields (within 7%) for 6 MV and close to +/- 5% for 10 x 10 cm(2) fields in the 18- to 25-MV range. The TMR ratio method was not as good, being within about +/- 5% to 7% of measurements only for 6 x 6 to 10 x 10 cm(2) fields at 6 MV and 10 x 10 cm(2) fields at the higher energies. Both simple 1D correction methods performed almost as well as Pinnacle for the bone-soft tissue cases. We recommend that if direct measurement of dose for heterogeneous treatment plans is not practiced, then one of these simple cross checks be performed to assure patient safety.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2009.01.002DOI Listing

Publication Analysis

Top Keywords

cm2 fields
20
monitor unit
12
field size
12
field sizes
12
planning systems
8
data acquired
8
cm2
8
range energies
8
lung-tissue interfaces
8
energies field
8

Similar Publications

This study presents an innovative glucose detection platform, featuring a highly sensitive, non-enzymatic glucose sensor. The sensor integrates nickel nanowires and a graphene thin film deposited on the gate region of an extended-gate electric double-layer field-effect transistor (EGEDL-FET). This unique combination of materials and device structure enables superior glucose sensing performance.

View Article and Find Full Text PDF

Electrocatalytic materials with dual functions of oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) have received increasing attention in the field of zinc-air batteries (ZABs) research. In this study, bifunctional CoNC@NCXS catalysts were prepared by anchoring Co and N co-doped CoNC on N-doped carbon xerogel sphere (NCXS) based on the spatially confined domain effect and in-situ doping technique. CoNC@NCXS exhibited excellent ORR/OER activity in alkaline electrolytes with the ORR onset potential of 0.

View Article and Find Full Text PDF

Fast-Charging Lithium-Ion Batteries Enabled by Magnetically Aligned Electrodes.

ACS Nano

January 2025

Materials Science and Engineering Program and Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States.

With the increasing popularity of electric transportation over the past several years, fast-charging lithium-ion batteries are highly demanded for shortening electric vehicles' charging time. Extensive efforts have been made on material development and electrode engineering; however, few of them are scalable and cost-effective enough to be potentially incorporated into the current battery production. Here, we propose a facile magnetic templating method for preparing LiFePO (LFP) cathodes with vertically aligned graphene sheets to realize fast-charging properties at a practical loading of 20 mg cm.

View Article and Find Full Text PDF

: The aim of this study was to investigate the effect of substrate - polycaprolactone (PCL)-based porous membrane modified with rosmarinic acid (RA), (PCL-RA) and to determine the optimal values of low field laser irradiation (LLLT) as stimulators of biological response of RAW 264.7 macrophages. : The porous polymer membrane was obtained by the phase inversion method, the addition of rosmarinic acid was 1%wt.

View Article and Find Full Text PDF

In July 2023, panicle and leaf blight-like symptoms were observed from the rice () variety, PVL03, in research field plots in Louisiana (Rayne, LA 70578, USA; 30.21330⁰ N, 92.37309⁰ W).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!