[Kinetics of monochloramine decay in disinfection of drinking water].

Huan Jing Ke Xue

State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China.

Published: September 2009

The model of second-order reaction kinetics has been used to fit the monochloramine decay in water samples by nonlinear imitation. Several factors were investigated, including pH, temperature, carbonate, bromide, iodide concentrations and natural organic matters in this system. The results showed that pH value was an important factor on the monochloramine decay rate, especially when pH was below 7.0. Temperature and carbonate levels also had obvious effect on the monochloramine decay. Co-existence of bromide anions had different impact under different pH values. At pH 6.60, monochloramine decay rate tended to decrease dramatically with the increment of bromide levels. However, when pH was above 7.60, 0.1 mg/L of bromide hardly affected the decay rate of mononchloramine. Co-existence of iodide showed stronger effect on the decline rate of monochloramine than that of bromide. It was demonstrated that the second-order kinetic model could fit well the experimental results of monochloramine decay reaction under the conditions of bromide or iodide co-existence. The results of this study will be of benefit to the theory and technology of drinking water disinfection, especially for the reduction of DBPs and the control of disinfectant dosages in the area of coastland and estuary.

Download full-text PDF

Source

Publication Analysis

Top Keywords

monochloramine decay
24
decay rate
12
temperature carbonate
8
bromide iodide
8
decay
7
monochloramine
6
bromide
6
[kinetics monochloramine
4
decay disinfection
4
disinfection drinking
4

Similar Publications

Assessing excimer far-UVC (222 nm) irradiation for advanced oxidation processes: Oxidants photochemistry and micropollutants degradation.

Water Res

December 2024

Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China. Electronic address:

Article Synopsis
  • The KrCl* excimer lamp (UV222) is a mercury-free alternative to low-pressure mercury lamps (UV254) for UV-based advanced oxidation processes, offering higher photon energy and better performance.
  • A comprehensive study was conducted on various oxidants like hydrogen peroxide and persulfate, revealing that UV222 significantly enhances oxidant activation, with increased efficacy for degrading micropollutants compared to UV254.
  • PDS proved to be the most effective oxidant under UV222, achieving much higher rates of micropollutant elimination and requiring less energy, despite some interference from other water constituents.
View Article and Find Full Text PDF

We demonstrate the application of proton transfer time-of-flight mass spectrometry (PTR-TOF-MS) in monitoring the kinetics of disinfectant decay in water with a sensitivity one to three orders of magnitude greater than other analytical methods. Chemical disinfection inactivates pathogens during water treatment and prevents regrowth as water is conveyed in distribution system pipes, but it also causes formation of toxic disinfection by-products. Analytical limits have hindered kinetic models, which aid in ensuring water quality and protecting public health by predicting disinfection by-products formation.

View Article and Find Full Text PDF

It's getting hot in here: Effects of heat on temperature, disinfection, and opportunistic pathogens in drinking water distribution systems.

Water Res

August 2024

Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States.

As global temperatures rise with climate change, the negative effects of heat on drinking water distribution systems (DWDS) are of increasing concern. High DWDS temperatures are associated with degradation of water quality through physical, chemical and microbial mechanisms. Perhaps the most pressing concern is proliferation of thermotolerant opportunistic pathogens (OPs) like Legionella pneumophila and Naegleria Fowleri.

View Article and Find Full Text PDF

Efficacy of chlorine-based disinfectants to control Legionella within premise plumbing systems.

Water Res

August 2024

College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia.

Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.

View Article and Find Full Text PDF

Escherichia coli (E. coli) plays a central role as an indicator for fecal contamination to predict the possible presence of microbial pathogens in drinking water. Current detection methods for E.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!