Methods of measuring uncertainties in rigid body image registration of fan beam computed tomography (FBCT) to cone beam CT (CBCT) have been developed for automatic image registration algorithms in a commercial image guidance system (Synergy, Elekta, UK). The relationships between image registration uncertainty and both imaging dose and image resolution have been investigated with an anthropomorphic skull phantom and further measurements performed with patient images of the head. A new metric of target registration error is proposed. The metric calculates the mean distance traversed by a set of equi-spaced points on the surface of a 5 cm sphere, centred at the isocentre when transformed by the residual error of registration. Studies aimed at giving practical guidance on the use of the Synergy automated image registration, including choice of algorithm and use of the Clipbox are reported. The chamfer-matching algorithm was found to be highly robust to the increased noise induced by low-dose acquisitions. This would allow the imaging dose to be reduced from the current clinical norm of 2 mGy to 0.2 mGy without a clinically significant loss of accuracy. A study of the effect of FBCT slice thickness/spacing and CBCT voxel size showed that 2.5 mm and 1 mm, respectively, gave acceptable image registration performance. Registration failures were highly infrequent if the misalignment was typical of normal clinical set-up errors and these were easily identified. The standard deviation of translational registration errors, measured with patient images, was 0.5 mm on the surface of a 5 cm sphere centred on the treatment centre. The chamfer algorithm is suitable for routine clinical use with minimal need for close inspection of image misalignment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/54/24/002 | DOI Listing |
Multiplexed Immunofluorescence (MxIF) enables detailed immune cell phenotyping, providing critical insights into cell behavior within the tumor immune microenvironment (TIME). However, signal integrity can be compromised due to the complex cyclic staining processes inherent to MxIF. Hematoxylin and Eosin (H&E) staining, on the other hand, offers complementary information through its depiction of cell morphology and texture patterns and is often visually cross-referenced with MxIF in clinical settings.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
Case Western Reserve University, Department of Biomedical Engineering, Cleveland, Ohio, United States.
Purpose: We investigated the feasibility and advantages of using non-contrast CT calcium score (CTCS) images to assess pericoronary adipose tissue (PCAT) and its association with major adverse cardiovascular events (MACE). PCAT features from coronary computed tomography angiography (CCTA) have been shown to be associated with cardiovascular risk but are potentially confounded by iodine. If PCAT in CTCS images can be similarly analyzed, it would avoid this issue and enable its inclusion in formal risk assessment from readily available, low-cost CTCS images.
View Article and Find Full Text PDFPhys Imaging Radiat Oncol
January 2025
Aarhus University Hospital, Danish Centre for Particle Therapy, Palle Juul-Jensens Blvd. 25, 8200 Aarhus, Denmark.
Background And Purpose: Diffusion tensor imaging (DTI) has been proposed to guide the anisotropic expansion from gross tumor volume to clinical target volume (CTV), aiming to integrate known tumor spread patterns into the CTV. This study investigate the potential of using a DTI atlas as an alternative to patient-specific DTI for generating anisotropic CTVs.
Materials And Methods: The dataset consisted of twenty-eight newly diagnosed glioblastoma patients from a Danish national DTI protocol with post-operative T1-contrast and DTI imaging.
Med Phys
January 2025
Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
Background: Histotripsy is a non-invasive, non-ionizing, non-thermal focused ultrasound technique. High amplitude short acoustic pulses converge to create high negative pressures that cavitate endogenous gas into a bubble cloud leading to mechanical tissue destruction. In the United States, histotripsy is approved to treat liver tumors under diagnostic ultrasound guidance but in initial clinical cases, some areas of the liver have not been treated due to bone or gas obstructing the acoustic window for targeting.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedics, Qingdao Municipal Hospital, 1 Jiaozhou Road, Shinan District, QingDao, Shandong Province, 266399, China.
Background: Spacer-type tibial osteotomy have been proven a novel and effective osteotomy to treat osteoarthritis, while lack of comparison with other surgical methods in younger patients. This study aims to evaluate the short-term clinical outcomes of spacer-type tibial osteotomy versus open wedge high tibial osteotomy (OWHTO) and unicompartmental knee arthroplasty (UKA) for Kellgren-Lawrence (K-L) grade 3-4 osteoarthritis (OA) in patients younger than 65 years.
Methods: This retrospective study analyzed a total of 224 patients with K-L grade 3-4 knee OA treated from March 2018 to November 2020.