The use of an amorphous silicon electronic portal imaging device (EPID) and Monte Carlo calculations were investigated for pretreatment fluence verification in intensity modulated stereotactic radiotherapy (IMSRT). Monte Carlo calculations were performed using BEAM, a general purpose Monte Carlo code to simulate radiation beams from radiotherapy units. The dose distribution to the EPID phosphor was calculated by BEAM and then converted to pixel value using a pixel calibration curve. The calibration correlated calculated pixel dose to the measured pixel value for a range of open fields. Points within the region bounded by the photon jaws were extracted for comparison. Criteria for successful verification were 5% local percent difference in high dose regions, 1 mm distance to agreement in high gradient regions, or 2% of the Monte Carlo calculated central axis pixel value in low dose regions. Software was written to quantitatively compare the measured and calculated EPID images. Successful verification of the modulated field required that >or=95% of compared points fall within the comparison criteria. Dose response of the EPID was found to be linear with Monte Carlo calculated doses over the dose ranges examined in this work Comparison of the measured and calculated EPID dose distributions showed good agreement with 97% of the points passing criteria. The sensitivity of the methodology to detect field shaping errors was tested by introducing positioning errors in segments of the modulated field. These sensitivity tests indicate that the comparison software designed for this work can detect a 1 mm positioning error in a single segment of the composite IMSRT field. It should be noted, however, that the work presented here is a proof of concept and currently not a clinically viable QA tool. It represents a limited evaluation using a single IMSRT field, and verification of additional fields will be required for a comprehensive evaluation of the described methods before broad conclusions can be drawn. Additionally, the results of this work are subject to the comparison criteria that were used. Clinical implementation of the proposed technique should be evaluated for the specific institutional criteria where it will be employed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/153303460900800603 | DOI Listing |
Sci Rep
January 2025
LCEA Laboratory, Faculty of Sciences, Mohammed Premier University, Oujda, Morocco.
In the current investigation, the efficiency inhibition of two newly synthesized bi-pyrazole derivatives, namely 2,3-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] pyridine (Tetra-Pz-Ortho) and 1,4-bis[(bis((1 H-pyrazol-1-yl) methyl) amino)] benzene (Tetra-Pz-Para) for corrosion of carbon steel (C&S) in 1 M HCl medium was evaluated. A Comparative study of inhibitor effect of Tetra-Pz-Ortho and Tetra-Pz-Para was conducted first using weight loss method and EIS (Electrochemical Impedance Spectroscopy) and PDP (Potentiodynamic Polarisation) techniques. Tetra-Pz-Ortho and Tetra-Pz-Para had a maximum inhibition efficacy of 97.
View Article and Find Full Text PDFPhys Eng Sci Med
January 2025
Department of Physics and Radiation Safety, Nepean Hospital, Penrith, New South Wales, Australia.
The radiation exposure to bystanders from nuclear medicine patients is a common concern raised in nuclear medicine departments. The GATE (Geant4 Application for Tomographic Emission) Monte Carlo radiation transport application was used to estimate the dose to a bystander. Two voxelised phantoms were utilised in a GATE Monte Carlo simulation as the radiation source and target.
View Article and Find Full Text PDFSci Rep
January 2025
Departamento de Ciencia de los Materiales e Ingeniería Metalúrgica y Química Orgánica, IMEYMAT, Universidad de Cádiz, Campus Río San Pedro, 11510, Puerto Real, Cádiz, Spain.
Polymer blending is an interesting strategy to broaden the combination of properties available for a variety of applications. To understand the behaviour of the new materials obtained as well as the influence of the fabrication parameters used, methods to analyse the distribution of polymers in the blend with resolution below the micrometer are required. In this work, we demonstrate the capability of focused ion beam (FIB) tomography to provide 3D information of the polymer distribution in objects obtained by blending acrylonitrile-styrene-acrylate (ASA) with polycarbonate (PC) (50 wt%), fabricated by Fused Filament Fabrication (FFF) and by Injection Moulding (IM).
View Article and Find Full Text PDFLangmuir
January 2025
School of Chemical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia.
Ofloxacin, a commonly prescribed antibiotic, raises serious environmental concerns due to its persistence in aquatic systems. This study offers new insights into the environmental behavior of ofloxacin and its interactions with carbon-based adsorbents with the aim of enhancing our understanding of its removal mechanisms via adsorption processes. Using a comprehensive computational approach, we analyzed the speciation, pK values, and solubility of ofloxacin across various pH conditions, accounting for all four microspecies, including the often-overlooked neutral form.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
Flatiron Institute, Center for Computational Quantum Physics, New York, New York 10010, USA.
The two-dimensional electron gas (2DEG) is a fundamental model, which is drawing increasing interest because of recent advances in experimental and theoretical studies of 2D materials. Current understanding of the ground state of the 2DEG relies on quantum Monte Carlo calculations, based on variational comparisons of different Ansätze for different phases. We use a single variational ansatz, a general backflow-type wave function using a message-passing neural quantum state architecture, for a unified description across the entire density range.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!