Fifty-five patients with repair of tetralogy of Fallot were evaluated with treadmill exercise, pulmonary function testing and rest two-dimensional and Doppler echocardiography to determine the relation among cardiopulmonary function, exercise capacity and ventricular arrhythmias. The mean age at repair was 8.1 +/- 2.1 years; age at the time of study ranged from 15 to 37 years (mean follow-up time after repair 18 +/- 5 years). Exercise duration was 92 +/- 17% of predicted. Maximal heart rate was 94 +/- 7% of predicted. No exercise test was stopped because of an arrhythmia. Thirty patients had oxygen consumption and ventilation measured during their final minute of exercise. Peak oxygen consumption was 31 +/- 8 ml/kg per min (86 +/- 18% of predicted). Twenty-five patients (45%) had low vital capacity at rest (less than 80% of predicted). Pulmonary regurgitation was identified in 42 (75%) of the patients and judged to be moderate in 10 (18%). Mild tricuspid valve regurgitation was identified in 64%. Doppler estimated right ventricular outflow gradient was greater than 15 mm Hg in 15% of the patients (mean gradient 24 mm Hg [range 16 to 56]). Age at repair, duration of follow-up and type of repair did not correlate with echocardiographic variables, ventilatory data, exercise performance or arrhythmias. Moderate pulmonary regurgitation was associated with increased right ventricular diastolic area and both were inversely related to exercise duration and vital capacity. Decreased breathing reserve during maximal exercise was associated with moderate pulmonary regurgitation and decreased vital capacity. The results indicate that exercise capacity in these patients is in general good; however, right ventricular volume loading and ventilatory dysfunction may produce exercise limitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(10)80116-0 | DOI Listing |
Zhonghua Er Ke Za Zhi
January 2025
Heart Center, Women and Children's Hospital, Qingdao University, Qingdao266034, China.
To evaluate the clinical efficacy of percutaneous balloon pulmonary valvuloplasty (PBPV) via antegrade venous-arterial loop in neonates with critical pulmonary stenosis with intact ventricular septum (CPS-IVS). A retrospective case review was conducted. Fifteen neonates with CPS-IVS who underwent PBPV via antegrade venous-arterial loop at the Women and Children's Hospital, Qingdao University between September 2020 and September 2023 were included.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
University Medical Center Göttingen, Department of Cardiology and Pneumology, Georg-August University, Robert-Koch-Str. 40, 37099, Göttingen, Germany.
Background: Pulmonary stenosis (PS) is common in congenital heart disease and an integral finding in Tetralogy of Fallot (TOF). Pulmonary regurgitation (PR) is more commonly found following surgery in repaired TOF. We aimed to evaluate the haemodynamic effects of PS and PR on cardiac physiology in a porcine model using cardiac magnetic resonance-based feature tracking (CMR-FT) deformation imaging.
View Article and Find Full Text PDFAlthough the long-term outcomes of the surgical grafts are well defined and reported, the data regarding the mid-and long-term results of the balloon-expandable percutaneous valves in the native right ventricular outflow tract (RVOT) is limited. We retrospectively evaluated 42 patients who underwent PPVI (Sapien® XT valve) to native RVOT due to severe pulmonary regurgitation (PR) and/or moderate to severe pulmonary stenosis (PS) between August 2015 and November 2020. The median patient age at the time of PPVI was 13.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Institute for Health Transformation, Western Health, Melbourne, Australia.
Background: In adults the Ross procedure provides an excellent alternative to prosthetic valves, but it is underutilised because of concerns about technical complexity, durability, and perceived high late reoperation rates. The inclusion technique stabilizes the aortic root, prevents dilatation, and respects the dynamic root physiology. Long-term outcomes of the Ross procedure with the inclusion cylinder technique (1992-2022) are reported.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Background: Real-time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!