[Undetected surgical glove perforation during emergency procedures].

Rev Assoc Med Bras (1992)

Departamento de Cirurgia, Faculdade de Ciências Médicas da Santa Casa de São Paulo, São Paulo, SP.

Published: September 2010

Objective: Gloves are the most important barriers that protect hospital personnel and patients. Unfortunately, glove perforation rates reach up to 78% in high risk procedures. The purpose of this prospective study was to evaluate the glove perforation rate in emergency procedures carried out in the Emergency Service of 'Santa Casa de São Paulo', School of Medicine.

Methods: The study analyzed all gloves used in the emergency room during a 2 months period. Gloves were tested immediately after the surgical procedure using the approved standardized water leak method.

Results: A total of 252 surgical gloves used by residents in 42 surgical procedures and 2361 gloves used in emergency procedures were tested for the presence of punctures by the water insuflation method. Forty one (16.3%) of the gloves tested showed at least one puncture, 18 (33%) in traumatic emergencies. The overall perforation rate in the emergency room was 7,3%.

Conclusion: We concluded that the incidence of punctures in gloves during surgical procedures was high, and occurred mostly with surgeons.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0104-42302009000500026DOI Listing

Publication Analysis

Top Keywords

glove perforation
12
perforation rate
8
rate emergency
8
emergency procedures
8
gloves emergency
8
emergency room
8
gloves tested
8
surgical procedures
8
gloves
7
emergency
6

Similar Publications

Intramedullary nail fixation is a routine procedure for treatment of intertrochanteric fractures. Aseptic technique is vital for reducing postoperative complications, as intraoperative glove perforations increase the risk of surgical site infections. The aim of this study was to determine the incidence of surgical glove perforation during intramedullary nailing of intertrochanteric fractures and to identify surgery-specific steps at risk.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to assess and compare the efficacy of Erich Arch Bar (EAB), Inter Maxillary Fixation (IMF) screws and SMART Lock Hybrid arch bar (HABs) in the treatment of mandibular fractures.

Materials And Methods: A prospective randomized clinical study was carried out in the Department of Dentistry at ESIC Hospital in Hyderabad from August 2021 to August 2023. The study comprised of three groups (EAB group (31), IMF screw group (33) and HABs group (29)).

View Article and Find Full Text PDF
Article Synopsis
  • The study assessed the integrity of non-sterile, powder-free latex gloves used by dental students across various specialties, finding a high rate of perforations (40.7%).
  • The gloves were analyzed using a modified water leak test after use in procedures like operative dentistry and oral surgery, revealing significant perforations mainly at the right thumb and index finger.
  • No statistical differences were found based on the type of dental procedure or duration of glove use, but there was a notable correlation between expected and actual defects in glove integrity.
View Article and Find Full Text PDF

Objective: To determine and compare the intraoperative durability of 4 major surgical glove brands.

Design Setting And Participants: This study is a randomized open-label clinical trial in which surgical gloves from 4 manufacturers are randomized to 5 surgical subspecialty study groups: (1) orthopedic surgery, (2) neurosurgery, (3) colorectal surgery, (4) trauma or acute general surgery, and (5) cardiac and plastic surgeries. The study was divided into 10 periods, with a cross-over design, and was conducted at a tertiary care academic medical center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!