Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To determine phenol red thread test (PRTT) values in eyes of clinically normal Hispaniolan Amazon parrots before and after topical application of an ophthalmic anesthetic agent and compare findings with Schirmer tear test (STT) values.
Design: Evaluation study.
Animals: 24 Amazona ventralis parrots from a research colony.
Procedures: On 4 occasions (1-week intervals), all birds underwent a thorough ophthalmic examination of both eyes, which included (in sequence) performance of a PRTT and an STT; topical ocular application of proparacaine hydrochloride; and performance of another PRTT and another STT. Correlations between PRTT and STT values recorded with and without topical anesthesia were assessed.
Results: Without topical anesthesia, mean +/- SD PRTT value was 12.5 +/- 5.0 mm/15 s (range, 1 to 25 mm/15 s). With topical anesthesia, the PRTT value was 12.6 +/- 5.4 mm/15 s (range, 2 to 24 mm/15 s). Without topical anesthesia, mean STT value was 7.9 +/- 2.6 mm/min (range, 0 to 13 mm/min). With topical anesthesia, the STT value was 5.1 +/- 3.3 mm/min (range, 0 to 18 mm/min). The correlation of PRTT and STT values recorded with or without topical anesthesia was weak (r = 0.51 and r = 0.32, respectively).
Conclusions And Clinical Relevance: Results indicated that the PRTT and STT were both viable methods for measurement of tear production in Hispaniolan Amazon parrots. Topical application of an ophthalmic anesthetic agent did not have a significant effect on the PRTT values but significantly decreased the STT values.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/javma.235.10.1181 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!